Analytical bias among different gas chromatographic approaches using standard BTX gases and exhaust samples.

J Sep Sci

Atmospheric Environment Laboratory, Department of Earth and Environmental Sciences, Sejong University, Seoul, Korea.

Published: February 2009

In this study, the analytical compatibility of the gas chromatographic (GC) approach was evaluated through a cross-calibration exercise. To this end, three aromatic volatile organic compounds (VOCs: benzene, toluene, and p-xylene (BTX)) were simultaneously analyzed with four individual instrumental setups (type I = GC with MS plus solid phase microextraction (SPME) method, II = GC with flame ionization detection (FID) plus SPME, III = fast GC-FID plus SPME, and IV = GC-FID plus air server/thermal desorption (AS/TD) method). A comparison of basic quality assurance (QA) data revealed considerable differences in DL values among the methods with moderate variabilities in the intercompound sensitivity. In light of the differences in detection properties, the analytical bias involved for each methodological approach was assessed by the relative relationship between analytes and basic operating conditions. The results suggest that the analysis of environmental samples at ultra-low concentration levels (at or below ppb level) can be subject to diverse sources of bias. Although detection properties of target compounds seem to be affected by the combined effects of various factors, changes in the sample concentration levels were seen to be the most consistent under the experimental setups analyzed in this study.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200800556DOI Listing

Publication Analysis

Top Keywords

analytical bias
8
gas chromatographic
8
detection properties
8
concentration levels
8
bias gas
4
chromatographic approaches
4
approaches standard
4
standard btx
4
btx gases
4
gases exhaust
4

Similar Publications

Official development agencies are increasingly supporting civil society lobby and advocacy (L&A) to address poverty and human rights. However, there are challenges in evaluating L&A. As programme objectives are often to change policies or practices in a single institution like a Government Ministry, L&A programmes are often not amenable to large-n impact evaluation methods.

View Article and Find Full Text PDF

This work provides a statistical analysis of four different approaches suggested in the literature for the estimation of an unknown concentration based on data collected using the standard addition method. These approaches are the conventional extrapolation approach, the interpolation approach, inverse regression, and the normalization approach. These methods are compared under the assumption that the measurement errors are normally distributed and homoscedastic.

View Article and Find Full Text PDF

Objective: Propose a framework to empirically evaluate and report validity of findings from observational studies using pre-specified objective diagnostics, increasing trust in real-world evidence (RWE).

Materials And Methods: The framework employs objective diagnostic measures to assess the appropriateness of study designs, analytic assumptions, and threats to validity in generating reliable evidence addressing causal questions. Diagnostic evaluations should be interpreted before the unblinding of study results or, alternatively, only unblind results from analyses that pass pre-specified thresholds.

View Article and Find Full Text PDF

Commutability is where the measurement response for a reference material (RM) is the same as for an individual patient sample with the same concentration of analyte measured using two or more measurement systems. Assessment of commutability is essential when the RM is used in a calibration hierarchy or to ensure that clinical measurements are comparable across different measurement procedures and at different times. The commutability of three new Standard Reference Materials (SRMs) for determining serum total 25-hydroxyvitamin D [25(OH)D], defined as the sum of 25-hydroxyvitamin D [25(OH)D] and 25-hydroxyvitamin D [25(OH)D], was assessed through an interlaboratory study.

View Article and Find Full Text PDF

The bioaccessibility of cadmium (Cd) and lead (Pb) in the gastrointestinal tract is crucial for health risk assessments of contaminated soils. However, variability in In vitro analytical conditions and soil properties introduces bias and uncertainty in predictions. This study employed three in vitro methods to measure Cd and Pb bioaccessibility during the gastric and gastrointestinal phases, using soil samples incubated for one year.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!