Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study evaluated the efficacy of tooth whitening and color stability at different time periods after treatment.
Materials And Methods: Blocks obtained from human molars were divided into 15 groups (n = 5) by bleaching agents: 35% hydrogen peroxide (Whiteness HP and Opalescence Xtra) and 37% carbamide peroxide (Whiteness Super); and light sources: halogen lamp and plasma arc lamp (bleach mode), LED/diode laser, argon laser, and no light source. The efficacy of bleaching was measured using a spectrophotometer. Six bleaching sessions were performed (times 1 to 6). The specimens were submitted to another reading 7, 15, and 30 days after the end of bleaching (times 7, 8, and 9). The results were submitted to ANOVA followed by Tukey test and polynomial regression (p < 0.05).
Results: Carbamide peroxide significantly differed from hydrogen peroxide, presenting low reflectance values. Activated versus non-activated bleaching did not differ significantly for any gel tested, except for Whiteness HP activated by argon laser, which presented the lowest mean reflectance values. The results obtained with hydrogen peroxide revealed a decrease in reflectance values one month after the end of treatment. For carbamide peroxide, this decrease was not observed.
Conclusion: The halogen lamp presented the same or higher efficacy than non-activated bleaching, which had a longer gel contact period. When hydrogen peroxide was used, a decrease in reflectance values was observed 30 days after the end of bleaching.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-849X.2008.00420.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!