A planar ultrasound transducer was modified by etching concentric circles on one surface of a piezoelectric ceramic to create four rings. The 10 cm diameter transducer had four active rings and an unenergized centre. The transducer housing was designed to be completely immersed in fluid, suitable for intraoperative hyperthermia. The transducer was resonant at 1.0 MHz and was tested in a water tank and in an acoustic absorbing medium where the steady-state temperatures were measured. A comparison between a single 10 cm element and the concentric ring modification with all rings at equal power density showed the performance to be nearly identical. In vivo experiments in canine thigh verified the phantom predictions as individual rings were energized. Theoretical intensity calculations were made and compared favourably to water tank test results. Clinical hyperthermia treatments for chest wall and head and neck tumours showed that the temperature distribution could be highly modified by adjusting the power to individual rings while holding the transducer stationary. Automated temperature mapping parallel to the transducer face was used to compare a single element applicator to the concentric ring applicator in clinical treatments on the same lesion. The concentric ring applicator was radially adjustable and was found to be advantageous in lowering the central peak temperatures and flattening the temperature distribution in tumours. A comparison between the single element clinical and operating room series showed that when pain is removed as a treatment limiting factor, higher central tumour temperatures are possible and more of the tumour volume achieves therapeutic temperatures. The concentric ring design improves the temperature distribution such that the higher central temperatures will not be necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/02656739109034971 | DOI Listing |
Neuroimage
January 2025
Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, USA. Electronic address:
Introduction: Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtzplatz 1, Eggenstein-Leopoldshafen, 76344, Germany.
The core advantage of metalenses over traditional bulky lenses lies in their thin volume and lightweight. Nevertheless, as the application scenarios of metalenses extend to the macro-scale optical imaging field, a contradiction arises between the increasing demand for large-aperture metalenses and the synchronous rise in design and processing costs. In response to the application requirements of metalens with diameter reaching the order of 10λ or even 10λ, this paper proposes a novel design method for fixed-height concentric-ring metalenses, wherein, under the constraints of the processing technology, a subwavelength 2D building unit library is constructed based on different topological structures, and the overall cross-section of the metalens is assembled.
View Article and Find Full Text PDFJ Pers Med
November 2024
Unit of Nephrology and Dialysis, Hypertension Excellence Centre, Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (PROMISE), Università di Palermo, 90128 Palermo, Italy.
The complications of hypertension depend not only on the mean blood pressure (BP) but also on its variability (BPV). Recent studies suggest that the choroid may serve as an indicator of systemic vascular damage. These studies have been made possible by the increased availability of optical coherence tomography (OCT).
View Article and Find Full Text PDFFluorescence emission regulation is of great interest for its promising applications in various fields such as microscopy, chemical analysis, encryption, and sensing. Most studies focus on the regulation of the fluorescence emission process. However, the spectral separation of excitation and emission of fluorophores requires careful design of resonances to cover both emission and excitation wavelengths, which is a better choice to enhance fluorescence intensity.
View Article and Find Full Text PDFNMR Biomed
February 2025
High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.
Deuterium metabolic imaging (DMI) is an emerging Magnetic Resonance technique providing valuable insight into the dynamics of cellular glucose (Glc) metabolism of the human brain in vivo using deuterium-labeled (H) glucose as non-invasive tracer. Reliable concentration estimation of H-Glc and downstream synthesized neurotransmitters glutamate + glutamine (Glx) requires accurate knowledge of relaxation times, but so far tissue-specific T and T relaxation times (e.g.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!