Evaluation of two nitrous oxide scavenging systems using infrared thermography to visualize and control emissions.

J Am Dent Assoc

School of Health Sciences, College of Pharmacy, Nursing and Health Sciences, Purdue University, West Lafayette, Ind., USA.

Published: February 2009

Background: The authors conducted a study to determine the effectiveness of two waste anesthetic gas-scavenging systems. They also evaluated one of the systems to determine the effect of work practices in controlling waste nitrous oxide (N2O).

Methods: The authors collected a minimum of 13 data sets in each phase of the study that included infrared thermography, digital videography and real-time air analysis for ambient concentrations of waste N2O. Surgeon 1, who had experience using both systems, used the Safe Sedate Dental Mask (Airgas, Radnor, Pa.) system (system I) in phase I and the Porter Nitrous Oxide Sedation System (Porter Instruments, Hatfield, Pa.) (system II) in phase II. Surgeon 2, who did not have experience using system I, used it in phase III. To evaluate each system's effectiveness, the authors collected N2O air concentration data from phases I and II and compared the data with the National Institute for Occupational Safety and Health Recommended Exposure Limit (NIOSH REL). They also compared phases I and III to determine the effect of work practices on the systems' effectiveness.

Results: Surgeon 1 controlled occupational exposure to N2O significantly better using system I than using system II. Mean N2O air concentration levels during phases I and II were 61.6 parts per million (ppm) and 225.6 ppm, respectively. Surgeon 2 did not achieve results comparable to those of surgeon 1 in phase I using system I. Infrared thermography and air concentration data suggested that key work practices and patient and surgical variables accounted for the different results obtained in phases I and III.

Conclusions: Although neither system was able to control occupational exposure of N2O oxide below the NIOSH REL, system I met the American Conference of Governmental Industrial Hygienists threshold limit value of less than 50 ppm during an eight-hour day and performed significantly better than did system II.

Clinical Implications: System I achieved maximal efficiency when combined with consistent best work practices.

Download full-text PDF

Source
http://dx.doi.org/10.14219/jada.archive.2009.0133DOI Listing

Publication Analysis

Top Keywords

work practices
16
nitrous oxide
12
infrared thermography
12
system
12
system phase
12
air concentration
12
determine work
8
authors collected
8
surgeon experience
8
system system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!