A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Finite element analysis of the effects of implant thread locations on stress distribution]. | LitMetric

[Finite element analysis of the effects of implant thread locations on stress distribution].

Hua Xi Kou Qiang Yi Xue Za Zhi

Dept. of Implant Centre, Stomatological College, Jilin University, Changchun 130041, China.

Published: December 2008

Objective: To investigate the effects of different implant thread locations on stress distribution in implant and bone under concentrated load, and discuss the best design of location of implant thread.

Methods: The stress in implant-bone interface of implants with different thread locations (model A, B, C, D), which were loaded in axial and oblique 450 to axle, were analyzed by Solidworks 2005 plus and Cosmos/works 7.0 software.

Results: The stresses in cervical cortical bone of implant with model C were lower than others. But under oblique load, the stresses of implant and cancellous bone in model C were higher than model A. The stresses distribution of model B was obviously concentrated, and under axial load, all kinds of stresses in this model were higher than others. The stress distribution in model A and D were more even, the stress concentrated more on implant neck, upper part of cortical bone and the lowest thread on implant. The stresses in interface under oblique load were much higher than those under axial load.

Conclusion: The location of thread has effect on stress distribution in implant-bone interface. More attention should be paid to it when we design implants, and we should try to avoid oblique load in implant prosthodontics.

Download full-text PDF

Source

Publication Analysis

Top Keywords

thread locations
12
stress distribution
12
oblique load
12
implant
9
effects implant
8
implant thread
8
locations stress
8
implant-bone interface
8
cortical bone
8
model higher
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!