Clinical and radiological mid-term results of the thrust plate prosthesis.

Int Orthop

Department of Orthopedics, Auguste Viktoria Klinik, Am Kokturkanal 2, 32545, Bad Oeynhausen, Germany.

Published: December 2009

The purpose of this study was to perform an objective clinical and radiological assessment of the thrust plate prosthesis (TPP). Fifty-three prostheses were evaluated clinically using the Harris hip score (HHS), visual analog scale (VAS), and radiographically before surgery, at the time of discharge, and postoperatively after on average of 8.09 (range 4.61-9.93) years. The average HHS significantly (p < or = 0.05) improved from 48 (range 18-77) points to 95 (range 46-100) points. The VAS revealed significant (p < or = 0.05) reduction of pain at rest and under load. Radiographic analysis showed a considerable potential for osteolysis under the thrust plate. Sixteen prostheses revealed signs of radiolucent zones. In general, there was a good clinical outcome with no major limitations in function. Radiographic changes under the thrust plate indicate an adaptation processes resulting from changed biomechanics. This study suggests that the TPP could be a good alternative in total hip replacement in younger patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2899180PMC
http://dx.doi.org/10.1007/s00264-008-0714-9DOI Listing

Publication Analysis

Top Keywords

thrust plate
16
clinical radiological
8
plate prosthesis
8
radiological mid-term
4
thrust
4
mid-term thrust
4
plate
4
prosthesis purpose
4
purpose study
4
study perform
4

Similar Publications

The 2024 Hualien M 7.4 earthquake struck the Longitudinal Valley, which accommodates the partial collision between the Eurasian and Philippine Sea plates. As the most significant event in Taiwan since the 1999 Chi-Chi M 7.

View Article and Find Full Text PDF

The uneven electric field and slow Zn desolvation lead to rapid dendrite growth during Zn plating and stripping, which severely deteriorates the performance of Zn metal anodes (ZMAs) in Zn-ion batteries (ZIBs). Although polymer-based artificial protective (PBAP) layers are widely applied to homogenize the electric field of ZMAs, they often fail to promote the desolvation process that eventually induces Zn dendrite growth. Herein, a bi-functional protective layer, comprising a finger-like porous matrix of polysulfone (PSF) and a hydroxyl-rich filler of agarose (AG), is constructed to suppress Zn dendrite growth.

View Article and Find Full Text PDF

The effects of pressure on anticipatory postural adjustments during a jump shot in basketball.

Gait Posture

October 2024

Institute of Health and Sport Sciences, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki 305-8574, Japan. Electronic address:

Article Synopsis
  • Anticipatory postural adjustments (APAs) are crucial for controlling dynamic movements like basketball jump shots, particularly under defensive pressure from a shot blocker.
  • A study involving 14 male university basketball players revealed that jump shots performed under pressure resulted in shorter APA duration but increased ground reaction force (GRF) and jump height.
  • The findings indicate that defensive pressure negatively impacts jump shot performance by shortening APAs and correlating increased sway during the adjustment phase with decreased shooting accuracy.
View Article and Find Full Text PDF

Linear ultrasonic motors can output large thrust stably in a narrow space. In this paper, a plate linear ultrasonic motor is studied. Firstly, the configuration and operating principle of the Π-type linear ultrasonic motor is illustrated.

View Article and Find Full Text PDF

Desiccation-induced cracks in a compacted clay liner significantly deteriorate the hydraulic barrier performance of landfill covers. The present study explores the effects of polypropylene (PP) fiber reinforcement on the hydrological response and crack resistance of compacted steel slag (SS; 90 wt%) - bentonite (10 wt%) mixtures under drying and wetting cycles. Comprehensive tests were conducted to explore the impact of different fiber lengths (6-12 mm) and contents (0-0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!