Rapid and reliable diagnosis of influenza is essential for identification of contagious patients and effective patient management. Near-patient assays allow establishment of the diagnosis within minutes in young children, and this study aimed to evaluate near-patient assays in relation to the patient's age. A total of 194 patients with laboratory-confirmed influenza A/H3N2 virus infection, diagnosed within a prospective cohort study, were included. Cryopreserved nasopharyngeal swabs collected from these patients were tested by four near-patient assays (Binax Now Influenza A&B, Quick S-Influ A/B, Influ-A&B Respi-Strip, and Actim Influenza A&B). The main outcome measure was sensitivity of the near-patient assays in relation to the age of patients. The Binax Now, Quick S-Influ, Influ-A&B Respi-Strip and Actim assays had overall sensitivities of 19%, 18%, 26%, and 40%, respectively. The estimated sensitivity for influenza A/H3N2 virus detection in nasopharyngeal swabs was 17-56% in children 1 year of age and decreased to 8-22% in patients 80 years of age (logistic regression). The sensitivity of the Influ-A&B Respi-Strip and Actim assays decreased significantly with increasing age (p 0.014 and p 0.033, respectively (logistic regression)), a trend for decrease was observed for the Binax Now assay (p 0.074 (logistic regression)), and the low sensitivity of the Quick S-Influ assay was similar in children and adults. Less than one-fourth of diagnosed influenza A/H3N2 virus infections can be identified in elderly patients using a near-patient assay. Consequently, near-patient assays are of limited value for confirming the diagnosis when influenza is clinically suspected in adults. Antiviral therapy and additional diagnostic procedures cannot be withheld on the basis of a negative near-patient assay result, particularly in adult patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7128506PMC
http://dx.doi.org/10.1111/j.1469-0691.2008.02674.xDOI Listing

Publication Analysis

Top Keywords

near-patient assays
24
diagnosis influenza
12
influenza a/h3n2
12
a/h3n2 virus
12
quick s-influ
12
influ-a&b respi-strip
12
respi-strip actim
12
logistic regression
12
near-patient
8
influenza
8

Similar Publications

Arterial and venous thromboembolism are leading causes of morbidity and death worldwide. Despite significant advances in the diagnosis, prognostication, and treatment of thrombotic diseases over the past 3 decades, the adoption of findings stemming from translational biomarker research in clinical practice remains limited. Biomarkers provide an opportunity to enhance our understanding of pathophysiological processes and optimize treatment strategies.

View Article and Find Full Text PDF

Objectives: The measurement of fasting glucose is a common practice for lowering the risk of hyperglycemia before an oral glucose tolerance test (OGTT). In this study we analyze advantages and limitations of near-patient measurement of capillary fasting glucose with a portable glucometer or blood sampling and measurement of plasma glucose with laboratory instrumentation.

Methods: The final study population consisted of 241 subjects (mean age: 36 ± 8 years; 97.

View Article and Find Full Text PDF

Background: Urinary tract infections are diagnosed by general practitioners based on symptoms, dipstick tests in some and laboratory urine culture. Patients may be given inappropriate antibiotics. Point-of-care tests can diagnose urinary tract infection in near-patient settings quicker than standard culture.

View Article and Find Full Text PDF

Photonic and electrochemical biosensors for near-patient tests-a critical comparison.

Optica

October 2024

School of Physics, Engineering and Technology and York Biomedical Research Institute, University of York, York, UK.

Research into diagnostic biosensors is a vibrant field that combines scientific challenge with translational opportunities; innovation in healthcare is of great societal interest and is an essential element of future healthcare provision. Photonic and electrochemical biosensors are the dominant modalities, both scientifically and commercially, yet the two scientific communities largely remain separated and siloed. It seems astute to better understand what the two fields can learn from one another so as to progress the key scientific, translational, and commercial challenges.

View Article and Find Full Text PDF

Therapeutic drug monitoring (TDM), which involves measuring drug levels in patients' body fluids, is an important procedure in clinical practice. However, the analysis technique currently used, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!