Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.
Materials And Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3),square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.
Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees ) followed by groups T2 (0.747 degrees ), T3 (0.516 degrees ), and T4 (0.325 degrees ), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.
Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-849X.2008.00325.x | DOI Listing |
J Bone Joint Surg Am
January 2025
Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY.
Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA).
Methods: MSSA and E.
Sci Rep
January 2025
Department of Orthopedics, Harbin 242 Hospital, Harbin, 150066, Heilongjiang Province, People's Republic of China.
Osteoporotic vertebral compression fractures (OVCFs) can be painful. Percutaneous kyphoplasty (PKP) aims at strengthening the vertebra and reducing pain, but efficacy can vary among patients. The purpose of this study was to establish a risk prediction model for pain relief following PKP in patients with OVCF.
View Article and Find Full Text PDFJ Dent
January 2025
DDS, MS, PhD, Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Brazil. Electronic address:
Objective: To evaluate the influence of different cleaning methods, surface treatments, and aging on the repair bond strength to a CAD/CAM glass-ceramic.
Materials And Methods: Forty-eight lithium disilicate CAD/CAM ceramic blocks were fabricated, sintered, and embedded in acrylic resin. After contamination with human saliva, they were divided according to the factors "Cleaning method" (Control-water/air spray, Air-particle abrasion with AlO, Ivoclean cleaning paste), "Surface treatment" (5% Hydrofluoric acid-HF + Silane, Monobond Etch & Prime-MEP), and "Aging" (thermocycling, no thermocycling).
ChemSusChem
January 2025
VITO NV, Match Unit, BELGIUM.
The growing pursuit of carbon circularity in material fabrication has led to the increased use of recycled and biobased resources, especially in epoxy resin systems. Fossil-based bisphenols are being replaced with recycled bisphenol A (r-BPA) and lignin derivatives, both derived from previous processes. In this study, r-BPA was chemically recycled from end-of-life televisions, then converted into r-DGEBA and r-DAGBA through glycidylation and acrylic acid ring-opening.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Department of Chemistry and Centre of Advanced Studies in Chemistry, Panjab University, Chandigarh, 160014, India; Department of Applied Chemistry, Maulana Abul Kalam Azad University of Technology, Simhat, Haringhata, West Bengal, 741249, India. Electronic address:
Background: The intellectual progress in fabricating artificial probes for selective appraisal of biologically admissible amino acids has displayed exponential growth in recent era.The neoteric era in material science has witnessed the significant application of carbon quantum dots (CQDs). However, the hybrid microgel of CQDs was less explored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!