Background: Cone beam computed tomography (CBCT) has become an extremely useful technique for dentomaxillofacial imaging because it provides clear images of highly contrasted structures. Previous studies evaluating the applicability of this technique in otologic imaging were very encouraging but were only performed in vitro on temporal bone specimens. The intracochlear positioning of the individual electrodes after cochlear implantation by means of CBCT has not yet been shown in vivo.

Objective: We describe a protocol for in vivo postoperative imaging of cochlear implants by CBCT. Moreover, the effective dose was measured and compared with the effective dose used on 4- and 16-slice multislice computed tomography (MSCT) by using a RANDO-phantom.

Main Outcome Measure: Developing a protocol for in vivo postoperative imaging of cochlear implants by CBCT.

Results: CBCT provides high-resolution and almost artifact-free multiplanar reconstruction images allowing assessment of the precise intracochlear position of the electrode and visualization of each of the individual contacts. The calculated effective dose of the used CBCT and MSCT acquisitions is 80 musv for the CBCT, 3,600 musv for the 16-slice computed tomography, and 4,800 musv for the 4-slice computed tomography.

Conclusion: These preliminary results suggests that, for in vivo postoperative evaluation of cochlear implants, CBCT can provide at least the same information as conventional radiography, digital radiograph, and MSCT but in a more comfortable and a much more safer way.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0b013e31819679f9DOI Listing

Publication Analysis

Top Keywords

computed tomography
16
vivo postoperative
12
cochlear implants
12
effective dose
12
cone beam
8
beam computed
8
cochlear implantation
8
protocol vivo
8
postoperative imaging
8
imaging cochlear
8

Similar Publications

Epilepsy Stands Nearby: A Pilot CT Perfusion Study on Post-Stroke Non-Convulsive Status Epilepticus.

Eur J Neurol

February 2025

IRCCS Istituto delle Scienze Neurologiche di Bologna, Department of Neurology and Stroke Center, Maggiore Hospital, Bologna, Italy.

Background: To investigate the relevance of hyperperfusion on computerised perfusion imaging (CTP) in the emergency setting in people with non-convulsive status epilepticus (NCSE) and previous stroke, to derive relevant aspects on the epileptogenic focus and the network recruited for NCSE propagation.

Methods: We enrolled consecutive adult patients with acute-onset NCSE and a previous stroke at a single institution undergoing CTP and EEG during symptoms. All patients underwent standard imaging including CT, CTP, CT angiograms and standard EEG within 30 min from hospital arrival.

View Article and Find Full Text PDF

Background: The use of iodinated contrast-enhancing agents in computed tomography (CT) improves the visualization of relevant structures for radiotherapy treatment planning (RTP). However, it can lead to dose calculation errors by incorrectly converting a CT number to electron density.

Purpose: This study aimed to propose an algorithm for deriving virtual non-contrast (VNC) electron density from dual-energy CT (DECT) data.

View Article and Find Full Text PDF

Purpose: To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm).

Methods: Patients undergoing clinical dual-energy EID-CT for known or suspected stone disease underwent same-day research PCD-CT. Patients with greater than 10 stones and no visible stones under 3 mm were excluded.

View Article and Find Full Text PDF

Medical image annotation is scarce and costly. Few-shot segmentation has been widely used in medical image from only a few annotated examples. However, its research on lesion segmentation for lung diseases is still limited, especially for pulmonary aspergillosis.

View Article and Find Full Text PDF

Influence of two different printing methods on the accuracy of full-guided implant insertion - a laboratory study in undergraduate dental students.

BDJ Open

January 2025

Department of Oral and Maxillofacial Surgery (Head: Prof. Dr. Dr. Bernd Lethaus), University Hospital Tübingen, Eberhard Karls Universität Tübingen, Osianderstr. 2-8, D-72076, Tübingen, Germany.

Objectives: The aim of the present study was to compare the accuracy of fully guided implant insertion in vitro achieved by two fabrication methods in a cohort of undergraduates. We hypothesized that both methods achieve a comparable accuracy.

Methods: Surface scans and cone beam computed tomography images of 48 mandibular models were matched.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!