Field validity and feasibility of four techniques for the detection of Trichuris in simians: a model for monitoring drug efficacy in public health?

PLoS Negl Trop Dis

Department of Virology, Parasitology & Immunology, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.

Published: March 2010

Background: Soil-transmitted helminths, such as Trichuris trichiura, are of major concern in public health. Current efforts to control these helminth infections involve periodic mass treatment in endemic areas. Since these large-scale interventions are likely to intensify, monitoring the drug efficacy will become indispensible. However, studies comparing detection techniques based on sensitivity, fecal egg counts (FEC), feasibility for mass diagnosis and drug efficacy estimates are scarce.

Methodology/principal Findings: In the present study, the ether-based concentration, the Parasep Solvent Free (SF), the McMaster and the FLOTAC techniques were compared based on both validity and feasibility for the detection of Trichuris eggs in 100 fecal samples of nonhuman primates. In addition, the drug efficacy estimates of quantitative techniques was examined using a statistical simulation. Trichuris eggs were found in 47% of the samples. FLOTAC was the most sensitive technique (100%), followed by the Parasep SF (83.0% [95% confidence interval (CI): 82.4-83.6%]) and the ether-based concentration technique (76.6% [95% CI: 75.8-77.3%]). McMaster was the least sensitive (61.7% [95% CI: 60.7-62.6%]) and failed to detect low FEC. The quantitative comparison revealed a positive correlation between the four techniques (Rs = 0.85-0.93; p<0.0001). However, the ether-based concentration technique and the Parasep SF detected significantly fewer eggs than both the McMaster and the FLOTAC (p<0.0083). Overall, the McMaster was the most feasible technique (3.9 min/sample for preparing, reading and cleaning of the apparatus), followed by the ether-based concentration technique (7.7 min/sample) and the FLOTAC (9.8 min/sample). Parasep SF was the least feasible (17.7 min/sample). The simulation revealed that the sensitivity is less important for monitoring drug efficacy and that both FLOTAC and McMaster were reliable estimators.

Conclusions/significance: The results of this study demonstrated that McMaster is a promising technique when making use of FEC to monitor drug efficacy in Trichuris.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2621347PMC
http://dx.doi.org/10.1371/journal.pntd.0000366DOI Listing

Publication Analysis

Top Keywords

drug efficacy
16
validity feasibility
8
detection trichuris
8
monitoring drug
8
efficacy estimates
8
ether-based concentration
8
trichuris eggs
8
techniques
5
field validity
4
feasibility techniques
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!