A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surface molecular imprinting on Mn-doped ZnS quantum dots for room-temperature phosphorescence optosensing of pentachlorophenol in water. | LitMetric

Surface molecular imprinting on Mn-doped ZnS quantum dots for room-temperature phosphorescence optosensing of pentachlorophenol in water.

Anal Chem

Research Center for Analytical Sciences, College of Chemistry, Nankai University, 94 Weijin Road, Tianjin 300071, China.

Published: February 2009

A new type of molecularly imprinted polymer (MIP)-based room-temperature phosphorescence (RTP) optosensor was developed by anchoring the MIP layer on the surface of Mn-doped ZnS quantum dots (QDs) via a surface molecular imprinting process. The synergetic combination of the RTP property of the Mn-doped ZnS QDs and the merits of the surface imprinting polymers not only improves the RTP selectivity of the Mn-doped ZnS QDs but also makes the MIP-based RTP optosensor also applicable to selective detecting of those nonphosphorescent analytes without the need for any inducers and derivatization. The new MIP-based RTP sensing protocol was applied to detect trace pentachlorophenol (PCP) in water samples without the interference of autofluorescence and scattering light of matrixes. The detection limit for PCP was 86 nM, and the precision for five replicate detections of 0.4 microM PCP was 2.8% (relative standard deviation). The recovery of spiked PCP in river water samples ranged from 93% to 106%.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac802375aDOI Listing

Publication Analysis

Top Keywords

mn-doped zns
16
surface molecular
8
molecular imprinting
8
zns quantum
8
quantum dots
8
room-temperature phosphorescence
8
rtp optosensor
8
zns qds
8
mip-based rtp
8
water samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!