A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CEC column behaviour of butyl and lauryl methacrylate monoliths prepared in non-aqueous media. | LitMetric

Polymeric monolithic stationary phases for capillary electrochromatography were prepared using two bulk monomers, butyl methacrylate (BMA) and lauryl methacrylate (LMA), by in situ polymerization in non-aqueous media. The effect of 1,4-butanediol/1-propanol ratio on porous properties was investigated separately for each monomer, keeping the proportion of monomers to pore-forming solvents fixed at 40:60 wt:wt. Also, mixtures of BMA and LMA at different 1,4-butanediol/1-propanol ratios were studied for tailoring the morphological features of the monolithic columns. The chromatographic performance of the different columns was evaluated by means of van Deemter plots of polycyclic aromatic hydrocarbons. Mercury-intrusion porosimetry, SEM, and nitrogen-adsorption measurements were also performed in order to understand their retention behaviour and porous properties. A comparison of these features was also performed for monoliths made with one bulk monomer (BMA or LMA) and with mixtures of both. These mixed monoliths showed satisfactory efficiencies and analysis times compared with those made with one bulk monomer; thus, the BMA-LMA monoliths constitute an attractive alternative to manipulate the electrochromatographic properties of methacrylate beds in CEC.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200800485DOI Listing

Publication Analysis

Top Keywords

lauryl methacrylate
8
non-aqueous media
8
porous properties
8
bma lma
8
bulk monomer
8
cec column
4
column behaviour
4
behaviour butyl
4
butyl lauryl
4
methacrylate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!