A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network. | LitMetric

A novel amperometric biosensor was fabricated based on the immobilization of cholesterol oxidase (ChOx) into a cross-linked matrix of chitosan (Chi)-room-temperature ionic liquid (IL) (1-butyl-3-methylimidazolium tetrafluoroborate). Initially, the surface of bare electrode (indium tin oxide coated glass) was modified with the electrodeposition of Au particles onto thiol (-SH) functionalized multi-walled carbon nanotubes (MWNTs). The biosensor electrode is designated as MWNT(SH)-Au/Chi-IL/ChOx. Scanning electron microscopy image of MWNT(SH)-Au/Chi-IL/ChOx reveals that Chi-IL exists as the interconnected wires covering the Au particles on the surface of MWNT(SH)-Au. Cyclic voltammetry and chronoamperometry were used for the electrochemical determination of cholesterol at the biosensor electrode, MWNT(SH)-Au/Chi-IL/ChOx. The presence of Au particles in the matrix of CNTs provides an environment for the enhanced electrocatalytic activities. The MWNT(SH)-Au/Chi-IL/ChOx biosensor exhibited a linear response to cholesterol in the concentration range of 0.5-5mM with a correlation coefficient of 0.998, good sensitivity (200 microAM(-1)), a low response time ( approximately 7s), repeatability (R.S.D value of 1.9%) and long term stability (20 days with a decrease of 5% response). The synergistic influence of MWNT(SH), Au particles, Chi and IL contributes to the excellent performance for the biosensor.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2008.11.034DOI Listing

Publication Analysis

Top Keywords

cholesterol biosensor
8
multi-walled carbon
8
ionic liquid
8
biosensor electrode
8
biosensor
6
development stable
4
cholesterol
4
stable cholesterol
4
biosensor based
4
based multi-walled
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!