Purpose: To investigate the impact of right ventricle (RV) contrast attenuation on the accuracy of RV function analysis at cardiac CT performed for coronary imaging.

Materials And Methods: We analyzed multi-phase cardiac dual-source CT studies of 40 consecutive patients (mean age 60.9+/-12.3 years; 13 women) with normal valve function. Function analyses of both the right and left ventricle (RV and LV) were performed using dedicated post processing software and stroke volumes (SV) were computed for each ventricle. The accuracy of the RV-SV measurements was determined based upon comparison to LV-SV measurement. The level of contrast attenuation of the RV was recorded at three separate regions of interest-below the pulmonary valve, mid-ventricular, and inferior RV. The accuracy of RV function assessment was correlated with the level of attenuation using regression analyses.

Results: There was a statistically significant correlation between the accuracy of RV function assessment and the level of RV attenuation in the inferior RV (adjusted R(2)=73.1%, p<0.0001). When compared to LV-SV measurements, in studies with low RV attenuation (<175 HUs, n=19) the mean deviation of RV-SV from LV-SV was 29.0+/-10.8 ml (42.1+/-13.9%). In studies with high RV attenuation (> or =175 HUs, n=21) the mean deviation of RV-SV from LV-SV was significantly lower 6.9+/-10.5 ml (9.9+/-16.0%).

Conclusion: The accuracy of RV function analysis is dependent on the level of contrast medium attenuation achieved in the inferior RV. There should be at least intermediate attenuation (>175 HUs) to enable accurate functional analysis. At low attenuation levels RV function parameters are prone to underestimation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2008.12.011DOI Listing

Publication Analysis

Top Keywords

contrast attenuation
12
accuracy function
12
attenuation accuracy
8
function analysis
8
analysis cardiac
8
function assessment
8
level attenuation
8
function
7
attenuation
6
accuracy
5

Similar Publications

ERP correlates of agency processing in joint action.

Soc Cogn Affect Neurosci

January 2025

Department of Psychology, University of Essex, Colchester, United Kingdom.

In the Ouija board phenomenon, the lack of agency experienced by the players leads them to attribute the movement of the planchette to spirits. The aim of this study was to investigate the neural and cognitive mechanisms involved in generating the sense of agency in such a joint action context. Two players (a participant and a confederate) jointly moved a Ouija board style planchette containing a wireless mouse.

View Article and Find Full Text PDF

Obesity, along with hypoxia, is known to be a risk factor for pulmonary hypertension (PH), which can lead to right ventricular hypertrophy and eventually heart failure. Both obesity and PH influence the autonomic nervous system (ANS), potentially aggravating changes in the right ventricle (RV). This study investigates the combined effects of obesity and hypoxia on the autonomic innervation of the RV in a mouse model.

View Article and Find Full Text PDF

Sarcopenia, the pathological age-related loss of muscle mass and strength, contributes to physical decline, frailty, and diminished healthspan. The impact of sarcopenia is expected to rise as the aging population grows, and treatments remain limited. Therefore, novel approaches for enhancing physical function and strength in older adults are desperately needed.

View Article and Find Full Text PDF

Metabolic requirements of dividing hepatocytes are prerequisite for liver regeneration after injury. In contrast to transcriptional dynamics during liver repair, its metabolic dependencies remain poorly defined. Here, we screened metabolic genes differentially regulated during liver regeneration, and report that SLC13A2, a transporter for TCA cycle intermediates, is decreased in rapid response to partial hepatectomy in mice and recovered along restoration of liver mass and function.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!