A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative analysis of temporal dynamics of EEG and phase synchronization of EEG to localize epileptic sites from high density scalp EEG interictal recordings. | LitMetric

Our objective was to examine if the high-density, 256 channel, scalp interictal EEG data can be used for localizing the epilepsy areas in patients. This was done by examining the long-range temporal correlations (LRTC) of EEGs and also that of the phase synchronization index (SI) of EEGs. It was found that the LRTC of scalp SI plots were better in localizing the seizure areas as compared with the LRTC of EEGs alone. The EEG data of one minute duration was filtered in the low Gamma band of 30-50 Hz. A detrended fluctuation analysis (DFA) was used to find LRTC of the scalp EEG data. Contour plots were constructed using a montage of the layout of 256 electrode positions. The SI was computed after taking Hilbert transform of the EEG data. The SI between a pair of channel was inferred from a statistical tendency to maintain a nearly constant phase difference over a given period of time even though the analytic phase of each channel may change markedly during that time frame. The SI for each electrode was averaged over with the nearby six electrodes. LRTC of the SI was computed and spatial plots were made. It was found that the LRTC of SI was highest at the location of the epileptic sites. A similar pattern was not found in the LRTC of EEGs. This provides a noninvasive way to localize seizure areas from scalp EEG data.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2008.4650224DOI Listing

Publication Analysis

Top Keywords

eeg data
20
scalp eeg
12
lrtc eegs
12
eeg
8
phase synchronization
8
epileptic sites
8
lrtc scalp
8
seizure areas
8
lrtc
7
scalp
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!