Respiratory motion varies on a daily basis in abdominal cancer patients, affecting the ability to successfully deliver local therapy and requiring increased treatment margins to account for this variation. Deformable registration techniques can accurately describe respiratory motion, however, online application can be limited by long computational times and user intervention. A technique has been developed to quickly quantify patient breathing motion from respiratory-sorted volumetric images by calculating 1D shifts in image intensities between spatially corresponding regions of interest (navigator channels) on patient's images. The 1D motion at the superior, inferior, anterior, and posterior liver edges was detected and applied to adapt a population liver respiratory motion model. For validation, deformable registration was performed for each patient using a validated technique, MORFEUS, for relative validation, and vessel bifurcations, identified on patient's inhale and exhale images, for absolute validation. The accuracy of the adapted-population model to describe the patient respiratory motion was (absolute mean +/- SD) 0.26 +/- 0.11 cm and 0.30 +/- 0.21 cm in the superior-inferior (SI) and anterior-posterior (AP) directions, respectively. The accuracy of predicting the tumor COM motion was 0.30 +/- 0.22 cm, and 0.34 +/- 0.31, while the absolute validation, based on bifurcations was 0.26 +/- 0.16 cm and 0.13 +/- 0.04 cm in the SI and AP directions, respectively. This technique was developed to complement and quickly adapt a full 3D biomechanical based deformable registration technique, MORFEUS, to be applied in the online setting.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2008.4650073DOI Listing

Publication Analysis

Top Keywords

respiratory motion
16
deformable registration
12
population liver
8
motion
8
technique developed
8
technique morfeus
8
absolute validation
8
026 +/-
8
030 +/-
8
+/-
7

Similar Publications

The global rise in work-related musculoskeletal ailments has led to issues like neck discomfort, scapular muscle dysfunction, reduced neck mobility, and functional limitations. This study aimed to evaluate the effectiveness of scapular functional exercises (SFE) and cervical isometric exercises (CIE) on pain, cervical range of motion (CROM), and functional limitations in individuals with chronic mechanical neck pain (CMNP). A two-arm, parallel group pretest-post-test randomized comparative trial was conducted.

View Article and Find Full Text PDF

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

Objectives: Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.

Methods: Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2).

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Background: Respiratory motion is a challenge for accurate radiotherapy that may be mitigated by real-time tracking. Commercial tracking systems utilize a hybrid external-internal correlation model (ECM), integrating continuous external breathing monitoring with sparse X-ray imaging of the internal tumor position.

Purpose: This study investigates the feasibility of using the next generation reservoir computing (NG-RC) model as a hybrid ECM to transform measured external motions into estimated 3D internal motions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!