Design and testing of an instrumentation system to reduce stimulus pulse amplitude requirements during FES.

Annu Int Conf IEEE Eng Med Biol Soc

School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.

Published: April 2009

Functional Electrical Stimulation (FES) has been used for decades to restore muscle function following neural trauma. Another promising use has been to maintain or increase muscle strength following injury. Unfortunately in the latter case there is considerable stimulation pain for the sensorially intact subject during effective levels of stimulation using surface electrodes. Recent research [1][2] has suggested using a constant long (up to 10 ms) low amplitude or ramped conditioning pulse just prior to the high amplitude stimulus pulse (100 - 200 microsec) to reduce the excitably of sensory nerve fibers. However, commercial muscle stimulators cannot be easily modified to provide such complex pulse patterns and flexible pulse train control. We have designed and implemented a novel, very flexible LabVIEW based monophasic constant current muscle stimulator that provides pulse trains with long duration prepulses and high voltage stimulus pulses with selectable shapes, amplitudes, durations and frequencies. As well, the stimulator system includes an isolated EMG amplifier to record the evoked M-waves, which are used to estimate the fraction of muscle motor units being stimulated. We are presently testing this system, by stimulating the median nerve of human subjects and measuring the evoked M-waves for a range of stimulus pulse amplitudes, preceded by either ramped or rectangular low amplitude prepulses. The results indicate that, rather than inhibiting the activation of motor axons, as has been suggested [4], the prepulses at very low amplitudes excite these axons to subthreshold levels. The amplitudes of the stimulus pulses can then be significantly reduced while still achieving high levels of muscle activation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2008.4649775DOI Listing

Publication Analysis

Top Keywords

stimulus pulse
12
low amplitude
8
stimulus pulses
8
evoked m-waves
8
pulse
7
muscle
6
stimulus
5
design testing
4
testing instrumentation
4
instrumentation system
4

Similar Publications

We tested Pekin ducks with playbacks of 5 different vocalizations plus a no noise and white noise stimulus as our controls (N = 15 ducks/sex/treatment). The "AM long" call is a common vocalization made by both sexes. "Honk" is also produced by both sexes and is thought to be an alarm or distress call.

View Article and Find Full Text PDF

Purpose: To assess the ability of the Dolphin air-pulse aesthesiometer to present multiple stimuli, which are separated temporally (in sequence) or spatially (simultaneously).

Methods: Two studies were performed to explore the cooling effects induced by double air-puff stimuli generated by a novel aesthesiometer composed of two micro-blower integrated units. The stimuli were delivered sequentially or simultaneously at the same or different spatial locations to an in vitro eye model monitored using thermography.

View Article and Find Full Text PDF

Traditional beat frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) are limited by short energy accumulation times and the necessity of a decay period, leading to weaker signals and longer measurement cycles. Herein, we present a novel optomechanical energy-enhanced (OEE-) BF-QEPAS technique for fast and sensitive gas sensing. Our approach employs periodic pulse-width modulation (PWM) of the laser signal with an optimized duty cycle, maintaining the quartz tuning fork's (QTF) output at a stable steady-state level by applying stimulus signals at each half-period and allowing free vibration in alternate half-periods to minimize energy dissipation.

View Article and Find Full Text PDF

Introduction: Lumbar transcutaneous spinal cord stimulation (TSS) evokes synchronized muscle responses, termed spinally evoked motor response (sEMR). Whether the structures TSS activates to evoke sEMRs differ when TSS intensity and waveform are varied is unknown.

Methods: In 15 participants (9F:6M), sEMRs were evoked by TSS over L1-L3 (at sEMR threshold and suprathreshold intensities) using conventional (one 400-µs biphasic pulse) or high-frequency burst (ten 40-µs biphasic pulses at 10 kHz) stimulus waveforms in vastus medialis (VM), tibialis anterior (TA) and medial gastrocnemius (MG) muscles.

View Article and Find Full Text PDF

The effective and translational strategy to regenerate knee meniscal fibrocartilage remained challenging. Herein, we first identified vascular smooth muscle cells (VSMCs) transdifferentiated into fibrochondrocytes and participated in spontaneous meniscal regeneration using smooth muscle cell lineage tracing transgenic mice meniscal defect model. Then, we identified low-intensity pulsed ultrasound (LIPUS) acoustic stimulus enhanced fibrochondrogenic transdifferentiation of VSMCs in vitro and in vivo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!