Reliable motion artifact detection for ECG monitoring systems with dry electrodes.

Annu Int Conf IEEE Eng Med Biol Soc

Institute for Information Processing Technology, University of Karlsruhe, 76131, Germany.

Published: May 2009

Reliable signals are the basic prerequisite for most mobile ECG monitoring applications. Especially when signals are analyzed automatically, capable motion artifact detection algorithms are of great importance. This article presents different artifact detection algorithms for ECG systems with dry electrodes. The algorithms are based on the measurement of additional parameters that are correlated with the artifacts. We describe a mobile measurement system and the procedure used for the evaluation of these algorithms. The algorithms are assessed based upon their effect on QRS detection. The best algorithm improved sensitivity (Se) from 98.7% to 99.8% and positive predictive value (+P) from 98.3% to 99.9%, while 15% of the signal was marked as artifact. This corresponds to a decrease in false positive and false negative detected beats by 89.9%. Different metrics to evaluate the performance of an artifact detection algorithm are presented.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2008.4649502DOI Listing

Publication Analysis

Top Keywords

artifact detection
16
motion artifact
8
ecg monitoring
8
systems dry
8
dry electrodes
8
detection algorithms
8
artifact
5
detection
5
algorithms
5
reliable motion
4

Similar Publications

Determination of the Time-frequency Features for Impulse Components in EEG Signals.

Neuroinformatics

January 2025

Institute of Mathematics, University of Kassel, Heinrich-Plett-Str. 40, Kassel, 34132, Germany.

Accurately identifying the timing and frequency characteristics of impulse components in EEG signals is essential but limited by the Heisenberg uncertainty principle. Inspired by the visual system's ability to identify objects and their locations, we propose a new method that integrates a visual system model with wavelet analysis to calculate both time and frequency features of local impulses in EEG signals. We develop a mathematical model based on invariant pattern recognition by the visual system, combined with wavelet analysis using Krawtchouk functions as the mother wavelet.

View Article and Find Full Text PDF

Measuring the effects of motion corruption in fetal fMRI.

Hum Brain Mapp

February 2025

Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.

Irregular and unpredictable fetal movement is the most common cause of artifacts in in utero functional magnetic resonance imaging (fMRI), affecting analysis and limiting our understanding of early functional brain development. The accurate detection of corrupted functional connectivity (FC) resulting from motion artifacts or preprocessing, instead of neural activity, is a prerequisite for reliable and valid analysis of FC and early brain development. Approaches to address this problem in adult data are of limited utility in fetal fMRI.

View Article and Find Full Text PDF

Cryopreservation of brain cell structure: a review.

Free Neuropathol

January 2024

Friedman Brain Institute, Departments of Pathology, Neuroscience, and Artificial Intelligence & Human Health, Icahn School of Medicine at Mount Sinai, New York, New York, USA.

Cryopreservation, the preservation of tissues at subzero temperatures, is a mainstay of brain banking that allows for the storage of brain tissue without the use of chemical fixatives. This is particularly important for molecular studies that are incompatible with tissue fixation. However, brain tissue is vulnerable to various forms of damage during the cryopreservation process, in particular due to the phase transition of water from a liquid to a solid state with the formation of ice crystals, which can disrupt cellular morphology.

View Article and Find Full Text PDF

Rationale And Objectives: The aim of this study was to compare the image quality of a deep learning (DL)-accelerated volumetric interpolated breath-hold examination (VIBE) sequence with a standard (ST) VIBE sequence in assessing the uterus.

Materials And Methods: Between April and December 2023, a total of 61 female patients (aged 41 ± 14 years) who were referred for an magnetic resonance imaging (MRI) of the pelvis were included in this prospective study, after providing informed consent. All examinations were performed with a 1.

View Article and Find Full Text PDF

Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.

J Magn Reson Imaging

January 2025

Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.

Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.

Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.

Study Type: Prospective.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!