Design of a wireless telemetric backpack device for real-time in vivo measurement of pressure-volume loops in conscious ambulatory rats.

Annu Int Conf IEEE Eng Med Biol Soc

Department of Electrical and Computer Engineering, ENS 634-A, C0803, The University of Texas at Austin, Austin, Texas 78712, USA.

Published: May 2009

Pressure - Volume (PV) analysis is the de facto standard for assessing myocardial function. Conductance based methods have been used for the past 27 years to generate instantaneous left ventricular (LV) volume signal. Our research group has developed the instrumentation and the algorithm for obtaining PV loops based on the measurement of real - time admittance magnitude and phase from the LV of anaesthetized mice and rats. In this study, the instrumentation will be integrated into an ASIC (Application Specific Integrated Circuit) and a backpack device will be designed along with this ASIC. This will enable measurement of real-time in vivo P-V loops from conscious and ambulatory rats, useful for both acute and chronic studies.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2008.4649322DOI Listing

Publication Analysis

Top Keywords

backpack device
8
real-time vivo
8
loops conscious
8
conscious ambulatory
8
ambulatory rats
8
design wireless
4
wireless telemetric
4
telemetric backpack
4
device real-time
4
vivo measurement
4

Similar Publications

The advancement of cellular networks requires updating measurement protocols to better study radiofrequency electromagnetic field (RF-EMF) exposure emitted from devices and base stations. This paper aims to present a novel activity-based microenvironmental survey protocol to measure environmental, auto-induced downlink (DL), and uplink (UL) RF-EMF exposure in the era of 5G. We present results when applying the protocol in Switzerland.

View Article and Find Full Text PDF

Postural disorders in children and adolescents have an increasing incidence. The aim of this study was to identify the type of postural defects in school-age and preschool children, as well as the external risk factors determined by an inadequate lifestyle. The research included 134 children aged between 5 and 18 years, in whom postural defects were identified.

View Article and Find Full Text PDF

Objective: Suspended loads have been shown to improve loaded-walking economy. Establishing a biped walking model with dynamic trunk pitch angles can provide more comprehensive estimates of the human biomechanical response under suspended loads.

Methods: We developed the trunk-load- hip dynamics, modified the spring-loaded-inverted-pendulum (SLIP) model, and optimized the loaded-walking pattern for minimal energetic cost.

View Article and Find Full Text PDF

Evaluation of the Working Mechanism of a Newly Developed Powered Ankle-Foot Orthosis.

Sensors (Basel)

October 2024

Department of Rehabilitation Sciences, Faculty of Movement and Rehabilitation Sciences, KU Leuven, 3001 Leuven, Belgium.

Ankle-foot orthoses (AFOs) are commonly prescribed to children with cerebral palsy (CP). The conventional AFO successfully controls the first and second ankle rocker, but it fails to correct the third ankle rocker, which negatively effects push-off power. The current study evaluated a new powered AFO (PAFO) design, developed to address the shortcomings of the conventional AFO.

View Article and Find Full Text PDF

Background: The prevalence of back and neck pain is common in children and adolescents, and in some series the numbers are alarming. Various risk factors have been identified, although some are controversial.

Objective: To determine the prevalence of neck and back pain in children and adolescents and to investigate the potential association with various risk factors identified in the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!