Aortic root replacement with stentless porcine xenografts: early and late outcomes in 132 patients.

Ann Thorac Surg

The Texas Heart Institute at St. Luke's Episcopal Hospital, and the Division of Cardiothoracic Surgery, Michael E. DeBakey Department of Surgery, Baylor College of Medicine, Houston, Texas, USA.

Published: February 2009

Background: Traditionally, aortic root replacement has most commonly involved mechanical composite valve grafts, which have excellent durability but necessitate lifelong anticoagulation. Stentless porcine xenografts (bioroots) are a recently developed alternative that enable root replacement without the necessity of long-term anticoagulation. This study examined the early and late outcomes of aortic root replacement with porcine bioroots.

Methods: Porcine bioroots were used for root replacement in 132 patients. Of these, 129 (97.7%) required graft extensions for ascending aortic replacement, and 55 (41.7%) underwent aortic arch replacement. Twenty-three operations (17.4%) were reoperations. Twenty-four patients (18.2%) had aortic dissection. Early and late outcomes were ascertained by reviewing medical records. Changes in New York Heart Association (NYHA) class were used to assess improvements in functional status. Follow-up echocardiography results were reviewed to assess bioprosthetic valve function and changes in left ventricular ejection fraction.

Results: There were 10 operative deaths (7.6%), 9 of which were directly related to intraoperative ventricular failure. Nine patients (6.8%) had late valve-related complications, including 5 patients with prosthetic endocarditis (3 died), 1 annular pseudoaneurysm, and 3 sudden, unexplained deaths. Survivors' NYHA status and left ventricular ejection fraction improved significantly. No structural valve dysfunction was evident during follow-up. Actuarial survival was 85.6% +/- 3.1% at 1 year and 77.8% +/- 4.8% at 5 years.

Conclusions: Aortic root replacement with porcine xenografts can be performed with respectable early and late outcomes, even when combined with aortic arch replacement. Further follow-up is necessary to evaluate long-term bioroot durability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2008.11.033DOI Listing

Publication Analysis

Top Keywords

root replacement
24
aortic root
16
early late
16
late outcomes
16
porcine xenografts
12
replacement
9
aortic
8
stentless porcine
8
132 patients
8
replacement porcine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!