Aims: Late stent malapposition (LSM) may be acquired (LASM) or persistent. LSM may play a role in patients who develop late stent thrombosis (ST). Our objective was to compare the risk of LASM in bare metal stents (BMS) with drug-eluting stents (DES) and to investigate the possible association of both acquired and persistent LSM with (very) late ST.

Methods And Results: We searched PubMed and relevant sources from January 2002 to December 2007. Inclusion criteria were: (a) intra-vascular ultrasonography (IVUS) at both post-stent implantation and follow-up; (b) 6-9-month-follow-up IVUS; (c) implantation of either BMS or the following DES: sirolimus, paclitaxel, everolimus, or zotarolimus; and (d) follow-up for LSM. Of 33 articles retrieved for detailed evaluation, 17 met the inclusion criteria. The risk of LASM in patients with DES was four times higher compared with BMS (OR = 4.36, CI 95% 1.74-10.94) in randomized clinical trials. The risk of (very) late ST in patients with LSM (five studies) was higher compared with those without LSM (OR = 6.51, CI 95% 1.34-34.91).

Conclusion: In our meta-analysis, the risk of LASM is strongly increased after DES implantation compared with BMS. Furthermore, LSM seems to be associated with late and very late ST.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurheartj/ehn553DOI Listing

Publication Analysis

Top Keywords

late stent
16
risk lasm
12
late
8
stent malapposition
8
stent thrombosis
8
persistent lsm
8
inclusion criteria
8
higher compared
8
compared bms
8
lsm
7

Similar Publications

Background: Coarctation of the aorta (CoA) is a narrowing of the aorta that affects 5-8% of congenital heart defects. Treatment options include surgical repair or transcatheter management with endovascular stenting or balloon dilatation. Late complications after operative repair include systemic hypertension, aortic valve abnormalities, aortic aneurysm, and recoarctation.

View Article and Find Full Text PDF

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Absorb Bioresorbable Vascular Scaffold: A Little Too Late.

JACC Cardiovasc Interv

January 2025

Brown University Health Cardiovascular Institute and the Division of Cardiology, Department of Medicine, Alpert Medical School, Providence, Rhode Island, USA. Electronic address:

View Article and Find Full Text PDF

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!