Effect of calibration method on Tekscan sensor accuracy.

J Biomech Eng

Department of Mechanical Engineering, University of British Columbia, 6250 Applied Science Lane, Vancouver, BC, V6R 2L7, Canada.

Published: March 2009

Tekscan pressure sensors are used in biomechanics research to measure joint contact loads. While the overall accuracy of these sensors has been reported previously, the effects of different calibration algorithms on sensor accuracy have not been compared. The objectives of this validation study were to determine the most appropriate calibration method supplied in the Tekscan program software and to compare its accuracy to the accuracy obtained with two user-defined calibration protocols. We evaluated the calibration accuracies for test loads within the low range, high range, and full range of the sensor. Our experimental setup used materials representing those found in standard prosthetic joints, i.e., metal against plastic. The Tekscan power calibration was the most accurate of the algorithms provided with the system software, with an overall rms error of 2.7% of the tested sensor range, whereas the linear calibrations resulted in an overall rms error of up to 24% of the tested range. The user-defined ten-point cubic calibration was almost five times more accurate, on average, than the power calibration over the full range, with an overall rms error of 0.6% of the tested range. The user-defined three-point quadratic calibration was almost twice as accurate as the Tekscan power calibration, but was sensitive to the calibration loads used. We recommend that investigators design their own calibration curves not only to improve accuracy but also to understand the range(s) of highest error and to choose the optimal points within the expected sensing range for calibration. Since output and sensor nonlinearity depend on the experimental protocol (sensor type, interface shape and materials, sensor range in use, loading method, etc.), sensor behavior should be investigated for each different application.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.3005165DOI Listing

Publication Analysis

Top Keywords

calibration
13
power calibration
12
rms error
12
range
9
calibration method
8
sensor
8
sensor accuracy
8
full range
8
tekscan power
8
calibration accurate
8

Similar Publications

Aim: Many combinations of inflammation-based markers have been reported their prognostic ability. The prognostic value of albumin-to-gama-glutamyltransferase ratio (AGR), an inflammation-related index, has been identified for several cancers. However, the predictive value of AGR for high-grade glioma patients remains unclear.

View Article and Find Full Text PDF

There are a variety of surgical conditions impacting the canine vagina and vestibule that require access through a caudal approach. A standard vertical episiotomy involves making an incision beginning ventral to the anus and extending ventrally through the dorsal commissure of the vulva and into the lumen of the vestibule and distal vagina. The objective of this study was to determine if complex vaginal procedures could be performed via a transverse perineal approach, thus eliminating the need to incise and reconstruct the vulva as performed in a standard episiotomy, and to evaluate the feasibility of vaginal resection with vulvar-sparing vestibular urethrostomy using this transverse approach.

View Article and Find Full Text PDF

Objective: To explore the risk factors for the reactivate of retinopathy of prematurity (ROP) after intravitreal injection of anti-vascular endothelial growth factor (VEGF) and to construct a nomogram model to predict the risk of ROP reactivate.

Methods: A retrospective analysis was conducted on 185 ROP children who underwent anti-VEGF treatment at the First Affiliated Hospital of Zhengzhou University from January 2017 to October 2023. They were randomly divided into a training set (129 cases) and a validation set (56 cases) at a ratio of 7:3.

View Article and Find Full Text PDF

As Water Sensitive Urban Design (WSUD) is a key strategy in integrated urban water management worldwide, there is a need for robust monitoring of WSUD systems. Being economical and flexible for operation and communication, low-cost sensor systems show great potential to mainstream digital water management. Yet, such systems are insufficiently tested, casting doubt on the reliability of their measurements.

View Article and Find Full Text PDF

Objective: This study aimed to explore the risk factors of hypokalemia after radical resection of esophageal cancer (EC) and establish a nomogram risk prediction model to evaluate hypokalemia risk after esophagectomy. Thus, this study provides a reference for the clinical development of intervention measures.

Methods: Clinical data of EC patients who underwent radical surgery from January 2020 to November 2022 in the First Affiliated Hospital of Guangxi Medical University were retrospectively collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!