An investigation of collagen fiber reorientation, as well as fluid and matrix movement of equine articular cartilage and subchondral bone under compressive mechanical loads, was undertaken using small angle X-ray scattering measurements and optical microscopy. Small angle X-ray scattering measurements were made on healthy and diseased samples of equine articular cartilage and subchondral bone mounted in a mechanical testing apparatus on station ID18F of ESRF, Grenoble, together with fiber orientation analysis using polarized light and displacement measurements of the cartilage matrix and fluid using tracers. At surface pressures of up to approximately 1.5 MPa, there was reversible compression of the tangential surface fibers and immediately subjacent zone. As load increased, deformation in these zones reached a maximum and then reorientation propagated to the radial deep zone. Between surface pressures of 4.8 MPa and 6.0 MPa, fiber orientation above the tide mark rotated 10 deg from the radial direction, with an overall loss of alignment. With further increase in load, the fibers "crimped" as shown by the appearance of subsidiary peaks approximately +/-10 deg either side of the principal fiber orientation direction. Failure at higher loads was characterized by a radial split in the deep cartilage, which propagated along the tide mark while the surface zone remained intact. In lesions, the fiber organization was disrupted and the initial response to load was consistent with early rupture of fibers, but the matrix relaxed to an organization very similar to that of the unloaded tissue. Tracer measurements revealed anisotropic solid and fluid displacement, which depended strongly on depth within the tissue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.3049478 | DOI Listing |
J Glaucoma
January 2025
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Prcis: Cognitive impairment in multiple domains was observed in primary open angle glaucoma patients as compared to age and gender matched healthy controls.
Objective: Evaluation of cognitive impairment in individuals with Primary Open Angle Glaucoma (POAG).
Methods: In this case-control study, individuals with POAG (cases, n=70) were compared with age- and sex-matched healthy individuals (controls, n=70) using detailed ophthalmological evaluation, cognitive assessment and serum cortisol level.
Macromol Rapid Commun
January 2025
State Key Laboratory of Advanced Fiber Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 200051, China.
Mechanically responsive polymer materials have garnered significant interest due to their unique ability to respond to external forces, leading to groundbreaking applications in visual stress mapping and damage detection. However, their use in fibers remains relatively unexplored. In this study, a mechanoresponsive polymer is synthesized by incorporating a spiropyran (SP) mechanophore into a polyurethane backbone.
View Article and Find Full Text PDFUnlabelled: Accurate localization of white matter pathways using diffusion MRI is critical to investigating brain connectivity, but the accuracy of current methods is not thoroughly understood. A fruitful approach to validating accuracy is to consider microscopy data that have been co-registered with MRI of post mortem samples. In this setting, structure tensor analysis is a standard approach to computing local orientations for validation.
View Article and Find Full Text PDFMater Today Bio
February 2025
State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, PR China.
Natural teeth fulfill functional demands by their heterogeneity. The composition and hydroxyapatite (HAp) nanostructured orientation of enamel differ from those of dentin. However, mimicking analogous materials still exhibit a significant challenge.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Fuzhou University, Fuzhou 350116, China.
Electronic grade hydrogen peroxide plays a crucial role in the fabrication of large-scale integrated circuits. However, hydrogen peroxide prepared by the anthraquinone method contains impurities such as lead ions (Pb) and phosphate, which can seriously affect the yield of the circuit. Traditional adsorbent materials have difficulty in solving the problem of simultaneous adsorption of trace anions and cations in hydrogen peroxide due to the single adsorption site and poor adsorption kinetics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!