Osseointegration implants have revolutionized craniofacial prosthetic reconstruction. Implant placement relies on adequate thickness and quality of bone to permit osseointegration. Positioning the implant is critical in craniofacial reconstruction because surface contours of the prosthesis must be preserved while housing attachment components securely and discretely. Also, the position of the final prosthesis must transition to native tissue smoothly. We report on the use of intraoperative stereotactic image guidance in the placement of implants for orbital, nasal, and auricular prosthetic reconstruction. Clinical data, intraoperative images, and postoperative rehabilitated results are presented to demonstrate the utility of the application of stereotactic image guidance for implant placement. In our experience, stereotactic image guidance facilitates optimal implant site selection if there is abnormal bone quantity or quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1001/archfacial.2008.510 | DOI Listing |
No Shinkei Geka
January 2025
Department for Neurosurgery, Aichi Cancer Center.
Historically, metastatic spinal tumors have been treated using open spinal fixation, invasive decompressive techniques, and low-dose palliative conventional external beam radiotherapy. As patients with metastatic disease are now living longer, the need for long-term local tumor control is becoming important. Spine stereotactic body radiotherapy has emerged as a valuable alternative option to achieve long-term local tumor control by delivering high doses of radiation to tumors and sparing the spinal cord.
View Article and Find Full Text PDFOper Neurosurg (Hagerstown)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.
View Article and Find Full Text PDFMed Phys
January 2025
Deparment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Background: Stereotactic radiosurgery (SRS) is widely used for managing brain metastases (BMs), but an adverse effect, radionecrosis, complicates post-SRS management. Differentiating radionecrosis from tumor recurrence non-invasively remains a major clinical challenge, as conventional imaging techniques often necessitate surgical biopsy for accurate diagnosis. Machine learning and deep learning models have shown potential in distinguishing radionecrosis from tumor recurrence.
View Article and Find Full Text PDFNeurosurgery
January 2025
Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Background And Objectives: Jugular paragangliomas (JPG) pose a surgical challenge because of their vascularity and complex location. Stereotactic radiosurgery (SRS) offers a minimally invasive management for patients with JPG. Our aim was to evaluate outcomes of Gamma Knife radiosurgery (GKRS) for the treatment of JPG over the long term.
View Article and Find Full Text PDFClin Transl Radiat Oncol
March 2025
Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550, Japan.
Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.
Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!