Background: Thin cap fibroatheroma (TCFA) is considered to be a vulnerable plaque. Virtual Histology-intravascular ultrasound (VH-IVUS) can precisely identify TCFA in vivo. Intense yellow plaque on angioscopy determined by quantitative colorimetry with L a b color space corresponds with histological TCFA; in particular, a plaque of color b value >23 indicates an atheroma with a fibrous cap thickness <100 mum. In the present study, the relationship between VH-TCFA and angioscopic plaque color determined by colorimetry was investigated.

Methods And Results: Fifty-seven culprit plaques in 57 patients were evaluated by VH-IVUS and angioscopy. VH-TCFA was defined as a plaque with a necrotic core >10% of plaque area without overlying fibrous tissue, and angioscopic TCFA was a plaque with b value >23. The frequency of angioscopic TCFA was higher in the VH-TCFA group than in the VH-non-TCFA group (74% vs 23%, P=0.0002). Moreover, yellow color intensity (b value) significantly correlated with plaque classification on VH-IVUS. When TCFA detected with angioscopy was used as the gold standard, the sensitivity, specificity, and accuracy for TCFA with VH-IVUS was 68%, 81%, and 75%, respectively.

Conclusions: VH-TCFA strongly correlated with angioscopic TCFA determined by a quantitative analysis with colorimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.cj-08-0762DOI Listing

Publication Analysis

Top Keywords

angioscopic tcfa
12
thin cap
8
cap fibroatheroma
8
yellow plaque
8
quantitative analysis
8
analysis colorimetry
8
tcfa
8
determined quantitative
8
tcfa plaque
8
plaque
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!