A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion's drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M + 2H](2+) or [M + 3H](3+) charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2651196 | PMC |
http://dx.doi.org/10.1021/ac801880a | DOI Listing |
Sci Data
January 2025
Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
As the occurrence of human diseases and conditions increase, questions continue to arise about their linkages to chemical exposure, especially for per-and polyfluoroalkyl substances (PFAS). Currently, many chemicals of concern have limited experimental information available for their use in analytical assessments. Here, we aim to increase this knowledge by providing the scientific community with multidimensional characteristics for 175 PFAS and their resulting 281 ion types.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056, Basel, Switzerland. Electronic address:
Background: The separation performance of drift tube ion mobility spectrometers is usually relatively weak with resolving powers well below 100. Improving this aspect requires, besides the optimization of other parameters, the challenging increase of the drift voltage as deduced from fundamental equations describing the broadening of a drifting ion swarm. We recently succeeded in constructing an improved high voltage instrument equipped with an electrospray source capable of analysing liquid samples with resolving powers above 200.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States.
Charge detection mass spectrometry (CDMS) allows direct mass measurement of heterogeneous samples by simultaneously determining the charge state and the mass-to-charge ratio (/) of individual ions, unlike conventional MS methods that use large ensembles of ions. CDMS typically requires long acquisition times and the collection of thousands of spectra, each containing tens to hundreds of ions, to generate sufficient ion statistics, making it difficult to interface with the time scales of online separation techniques such as ion mobility. Here, we demonstrate the application of Fourier transform multiplexing and drift tube ion mobility joined with Orbitrap-based CDMS for the analysis of multimeric protein complexes.
View Article and Find Full Text PDFEur J Mass Spectrom (Chichester)
January 2025
QuantumSIMM, Kangra, HP, India.
Phthalate esters, frequently used as plasticizers in consumer products, raise concerns because of potential health effects. Using density functional theory (DFT) with BLYP and 6-311++G(d, p) basis sets, their properties, such as dipole moment, polarizability, proton affinity and ionization energy of phthalate esters are obtained. Reaction kinetics and thermodynamics of popular reagent ions like HO, NH, NO and O are computed to know the feasibility of the reactions with such ions.
View Article and Find Full Text PDFSensors (Basel)
December 2024
UFZ Helmholtz Centre for Environmental Research, Department Monitoring and Exploration Technologies, Permoserstraße 15, 04318 Leipzig, Germany.
Ion mobility spectrometry is successfully used as a sensor technology for different applications. A feature of this method is that characteristic ion mobility spectra are obtained for each measurement rather than a sum signal. The spectra result from the different drift velocities of ions in a drift tube at atmospheric pressure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!