Frequency, types, and potential clinical significance of medication-dispensing errors.

Clinics (Sao Paulo)

Hôpital d'Instruction des Armées PERCY, Clamart Cedex, France.

Published: August 2009

Introduction And Objectives: Many dispensing errors occur in the hospital, and these can endanger patients. The purpose of this study was to assess the rate of dispensing errors by a unit dose drug dispensing system, to categorize the most frequent types of errors, and to evaluate their potential clinical significance.

Methods: A prospective study using a direct observation method to detect medication-dispensing errors was used. From March 2007 to April 2007, 'errors detected by pharmacists' and 'errors detected by nurses' were recorded under six categories: unauthorized drug, incorrect form of drug, improper dose, omission, incorrect time, and deteriorated drug errors. The potential clinical significance of the 'errors detected by nurses' was evaluated.

Results: Among the 734 filled medication cassettes, 179 errors were detected corresponding to a total of 7249 correctly fulfilled and omitted unit doses. An overall error rate of 2.5% was found. Errors detected by pharmacists and nurses represented 155 (86.6%) and 24 (13.4%) of the 179 errors, respectively. The most frequent types of errors were improper dose (n = 57, 31.8%) and omission (n = 54, 30.2%). Nearly 45% of the 24 errors detected by nurses had the potential to cause a significant (n = 7, 29.2%) or serious (n = 4, 16.6%) adverse drug event.

Conclusions: Even if none of the errors reached the patients in this study, a 2.5% error rate indicates the need for improving the unit dose drug-dispensing system. Furthermore, it is almost certain that this study failed to detect some medication errors, further arguing for strategies to prevent their recurrence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2671971PMC
http://dx.doi.org/10.1590/s1807-59322009000100003DOI Listing

Publication Analysis

Top Keywords

errors
13
potential clinical
12
'errors detected
12
errors detected
12
clinical significance
8
medication-dispensing errors
8
dispensing errors
8
unit dose
8
frequent types
8
types errors
8

Similar Publications

Inborn errors of immunity (primary immunodeficiencies).

Allergy Asthma Clin Immunol

January 2025

Division of Allergy and Clinical Immunology, Department of Pediatrics, Montreal Children's Hospital, McGill University Health Centre, Montreal, QC, Canada.

Primary immunodeficiencies (PID), now often referred to as inborn errors of immunity (IEI), are a large heterogeneous group of disorders that result from deficiencies in immune system development and/or function. IEIs can be broadly classified as disorders of adaptive immunity (e.g.

View Article and Find Full Text PDF

Background: Motion complexity is necessary for adapting to external changes, but little is known about trunk motion complexity during seated perturbation in individuals with spinal cord injury (SCI). We aimed to investigate changes following SCI in trunk segmental motion complexity across different perturbation directions and how they affect postural control ability in individuals with SCI.

Methods: A total of 17 individuals with SCI and 18 healthy controls participated in challenging sagittal-seated perturbations with hand protection.

View Article and Find Full Text PDF

Background: Natural language processing (NLP) enables the extraction of information embedded within unstructured texts, such as clinical case reports and trial eligibility criteria. By identifying relevant medical concepts, NLP facilitates the generation of structured and actionable data, supporting complex tasks like cohort identification and the analysis of clinical records. To accomplish those tasks, we introduce a deep learning-based and lexicon-based named entity recognition (NER) tool for texts in Spanish.

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or 700) and the dual Scheimpflug topography (Galilei G4).

Methods: Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4.

View Article and Find Full Text PDF

Transient changes in the firing of midbrain dopamine neurons have been closely tied to the unidimensional value-based prediction error contained in temporal difference reinforcement learning models. However, whereas an abundance of work has now shown how well dopamine responses conform to the predictions of this hypothesis, far fewer studies have challenged its implicit assumption that dopamine is not involved in learning value-neutral features of reward. Here, we review studies in rats and humans that put this assumption to the test, and which suggest that dopamine transients provide a much richer signal that incorporates information that goes beyond integrated value.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!