Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI.

J Cereb Blood Flow Metab

Department of Radiology, C.J. Gorter Center for High-Field MRI, Leiden University Medical Center, Leiden, The Netherlands.

Published: April 2009

One of the main difficulties in obtaining quantitative perfusion values from dynamic susceptibility contrast-magnetic resonance imaging is a correct arterial input function (AIF) measurement, as partial volume effects can lead to an erroneous shape and amplitude of the AIF. Cerebral blood flow and volume scale linearly with the area under the AIF, but shape changes of the AIF can lead to large, nonlinear errors. Current manual and automated AIF selection procedures do not guarantee the exclusion of partial volume effects from AIF measurements. This study uses a numerical model, validated by phantom experiments, for predicting the optimal location for AIF measurements in the vicinity of the middle cerebral artery (MCA). Three different sequences were investigated and evaluated on a voxel-by-voxel basis by comparison with the ground truth. Subsequently, the predictions were evaluated in an in vivo example. The findings are fourfold: AIF measurements should be performed in voxels completely outside the artery, here a linear relation should be assumed between DeltaR*2 and the concentration contrast agent, the exact optimal location differs per acquisition type, and voxels including a small MCA yield also correct AIF measurements for segmented echo planar imaging when a short echo time was used.

Download full-text PDF

Source
http://dx.doi.org/10.1038/jcbfm.2008.155DOI Listing

Publication Analysis

Top Keywords

aif measurements
16
optimal location
12
aif
9
arterial input
8
input function
8
middle cerebral
8
cerebral artery
8
partial volume
8
volume effects
8
measurements
5

Similar Publications

Synchronous vibrations, which are caused by periodic excitations, can have a severe impact on the service life of impellers. Blade Tip Timing (BTT) is a promising technique for monitoring synchronous vibrations due to its non-intrusive nature and ability to monitor all blades at once. BTT generally employs a Once-per-Revolution (OPR) sensor that is mounted on the shaft for blade identification and deflection calculation.

View Article and Find Full Text PDF

Experimental Study on Deep-Drawing Dies Made of Pre-Stressed UHPC.

Materials (Basel)

January 2025

Chair of Metal Forming and Casting, Technical University of Munich, Walther-Meissner-Strasse 4, 85748 Garching, Germany.

Deep drawing is a cost-efficient way of producing sheet metal parts in high production volumes. Prototypes and very small series are expensive due to the cost of steel-forming tools. Ultra-high-performance concrete (UHPC) tools offer a cheap and fast alternative to conventional steel-forming tools.

View Article and Find Full Text PDF

Obtaining the arterial input function (AIF) is essential for quantitative regional cerebral perfusion (rCBF) measurements using [O]HO PET. However, arterial blood sampling is invasive and complicates the scanning procedure. We propose a new non-invasive dual scan technique with an image derived input function (IDIF) from an additional heart scan.

View Article and Find Full Text PDF

Objective: The study aims to investigate the long-term impacts of traumatic brain injury (TBI) on neuroinflammation and neuronal apoptosis in pediatric and adult mice, specifically focusing on how age-at-injury influences these processes.

Methods: Controlled cortical impact (CCI) was used to induce TBI in pediatric (21-25 days old) and adult (8-12 weeks old) C57Bl/6 male mice. Neuroinflammation was evaluated through immunoreactivity for Iba-1 and GFAP, while apoptosis was assessed using markers such as Bax, Bcl- 2, and pro-caspase-3.

View Article and Find Full Text PDF

Mitochondrial metabolism requires the chaperoned import of disulfide-stabilized proteins via CHCHD4/MIA40 and its enigmatic interaction with oxidoreductase Apoptosis-inducing factor (AIF). By crystallizing human CHCHD4's AIF-interaction domain with an activated AIF dimer, we uncover how NADH allosterically configures AIF to anchor CHCHD4's β-hairpin and histidine-helix motifs to the inner mitochondrial membrane. The structure further reveals a similarity between the AIF-interaction domain and recognition sequences of CHCHD4 substrates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!