Gas chromatographic analysis of dimethyltryptamine and beta-carboline alkaloids in ayahuasca, an Amazonian psychoactive plant beverage.

Phytochem Anal

Department of Clinical and Toxicological Analysis, Faculty of Pharmaceutical Sciences, University of São Paulo, Av. Prof. Lineu Prestes 580 B13B, São Paulo, SP, Brazil.

Published: April 2009

Introduction: Ayahuasca is obtained by infusing the pounded stems of Banisteriopsis caapi in combination with the leaves of Psychotria viridis. P. viridis is rich in the psychedelic indole N,N-dimethyltryptamine, whereas B. caapi contains substantial amounts of beta-carboline alkaloids, mainly harmine, harmaline and tetrahydroharmine, which are monoamine-oxidase inhibitors. Because of differences in composition in ayahuasca preparations, a method to measure their main active constituents is needed.

Objective: To develop a gas chromatographic method for the simultaneous determination of dimethyltryptamine and the main beta-carbolines found in ayahuasca preparations.

Methodology: The alkaloids were extracted by means of solid phase extraction (C(18)) and detected by gas chromatography with nitrogen/phosphorous detector.

Results: The lower limit of quantification (LLOQ) was 0.02 mg/mL for all analytes. The calibration curves were linear over a concentration range of 0.02-4.0 mg/mL (r(2 )> 0.99). The method was also precise (RSD < 10%).

Conclusion: A simple gas chromatographic method to determine the main alkaloids found in ayahuasca was developed and validated. The method can be useful to estimate administered doses in animals and humans for further pharmacological and toxicological investigations of ayahuasca.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pca.1110DOI Listing

Publication Analysis

Top Keywords

gas chromatographic
12
beta-carboline alkaloids
8
alkaloids ayahuasca
8
chromatographic method
8
ayahuasca
6
method
5
gas
4
chromatographic analysis
4
analysis dimethyltryptamine
4
dimethyltryptamine beta-carboline
4

Similar Publications

A portable gas chromatograph-mass spectrometer (GC-MS) is an effective instrument for rapid on-site detection of volatile organic compounds (VOCs). Current instruments typically adsorb samples at ambient temperature, challenging the detection of low-boiling VOCs. In this study, a low-temperature adsorption thermal desorption method is proposed for sample enrichment in a portable GC-MS.

View Article and Find Full Text PDF

Column Screening and Development of HILIC and RPLC Methods Coupled to Tandem Mass Spectrometry for the Monitoring of Albumin on Cysteine 34 Exposed to Mustard Agents.

J Sep Sci

January 2025

Department of Analytical, Bioanalytical Sciences and Miniaturization (LSABM) Chemistry, Biology and Innovation (CBI), UMR CNRS-ESPCI Paris 8231, ESPCI Paris, PSL University, CNRS, Paris, France.

Adduction on protein nucleophile sites by mustard agents can be monitored to assess detection of retrospective exposure to these agents. Cysteine 34 (Cys34) on human serum albumin was selected as the target of choice. This work targets di- and tripeptides adducted on Cys34 by sulfur mustard, sesquimustard, and nitrogen mustards separated in hydrophilic liquid chromatography (HILIC) and Reversed-Phase (RP) mode.

View Article and Find Full Text PDF

Pine needle, pine bark, and soil samples were collected from various regions in South Korea, considering the suitability of vegetation samples as passive samplers. A total of 27 organochlorine pesticides (OCPs) were analyzed using a gas chromatograph/high-resolution mass spectrometer (GC/HRMS). The total concentrations of OCPs ranged between 650 and 3652 pg/g dw in soil, 215 and 1384 pg/g ww in pine needles, and 456 and 1723 pg/g ww in pine bark.

View Article and Find Full Text PDF

The evolution of precursors to form secondary organic aerosol (SOA) is still a challenge in atmospheric chemistry. Chamber experiments were conducted to simulate the ambient OH oxidation of naphthalene and α-pinene, which are typical markers of anthropogenic and biogenic emissions. Particulate matters were sampled by quartz filters and were analyzed by comprehensive two-dimensional gas chromatography (GC×GC) coupled with a thermal desorption system (TD) and a mass spectrometer (MS).

View Article and Find Full Text PDF

Leachables in drug products and from medical devices can adversely affect patient health and thus must be identified and quantified. Accurate and protective quantitation in target analysis for leachables (and extractables as potential leachables) is accomplished via compound-specific calibration curves. Quantification in non-targeted analysis (NTA) is complicated by the variable relative response factors (RRFs) among and between individual leachables and the circumstance that the leachables are not known until the NTA is completed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!