This study evaluates performance of nitrogen dioxide (NO2) and volatile organic compound (VOC) passive samplers with corresponding reference monitors at two sites in the Detroit, Michigan area during the summer of 2005. Ogawa passive NO2 samplers and custom-made, re-useable Perkin-Elmer (PE) tubes with Carbopack X sorbent for VOCs were deployed under week-long sampling periods for six weeks. Precise results (5% relative standard deviation, RSD) were found for NO2 measurements from collocated Ogawa samplers. Reproducibility was also good for duplicate PE tubes for benzene, toluene, ethylbenzene, and xylene isomers (BTEX species, all < or = 6% RSD). As seen in previous studies, comparison of Ogawa NO2 samplers with reference chemiluminescence measurements suggested good agreement. Generally good agreement was also found between the PE tubes and reference methods for BTEX species.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b809588dDOI Listing

Publication Analysis

Top Keywords

samplers reference
8
reference monitors
8
volatile organic
8
nitrogen dioxide
8
no2 samplers
8
btex species
8
good agreement
8
samplers
5
field comparison
4
comparison passive
4

Similar Publications

Rumen fistulation is a widely used procedure that allows for collection of ruminal contents. However, fistulation is an invasive and costly procedure that generally limits the number of animals that can be recruited for experiments, thus encouraging the use of alternative techniques such as the intra-esophageal tube technique. One of the challenges of this technique is the limited ability to collect solid fractions from the rumen content pool, which may affect the microbial community structure in the sample, particularly affecting the recovery and characterization of solid adherent bacteria.

View Article and Find Full Text PDF

This paper presents an approach to apply aquatic passive sampling (PS) in regulatory chemical water quality monitoring in Europe. Absorption-based passive sampling is well developed and suitable for the sampling of hydrophobic chemicals, some of which are European Water Framework Directive priority substances with Environmental Quality Standards (EQS) derived for biota. Considering a chemical activity approach to chemical risk assessment, we propose equilibrium concentration in lipids (from passive water sampling) as a reference value for measured concentrations in biota.

View Article and Find Full Text PDF

As SARS-CoV-2 continues to evolve and herd immunity establishes, an increasing number of asymptomatic infections have been reported, increasing the risk of airborne spread of the virus. Most of the studies regarding SARS-CoV-2 RNA presence in air refer to indoor environments, with few studies having reported SARS-CoV-2 RNA in outdoor air. The aim of this study was to assess the presence of SARS-CoV-2 RNA at two different settings, crowded outdoor versus empty outdoor environments in Valladolid, Spain, during winter 2021.

View Article and Find Full Text PDF

Developing a consistent model for predicting equilibration in polymeric passive samplers across various HOC classes in sediment pore water.

Chemosphere

November 2024

Department of Civil, Environmental and Construction Engineering, Texas Tech University, Lubbock, TX, 79409, USA; Department of Chemical Engineering, Texas Tech University, Lubbock, TX, 79409, USA. Electronic address:

The use of polymeric passive samplers (often polydimethylsiloxane, PDMS, or low-density polyethylene, LDPE) to indicate water concentrations of hydrophobic organic compounds under environmental conditions generally requires two key parameters, a compound-specific polymer-water equilibrium partition coefficient (K), and the degree of equilibration achieved in a given environmental exposure scenario. Herein, we have developed model to extrapolate equilibration of performance reference compounds between polymer and pore water across different compound classes that is also dependent upon accurate estimates of K. We have also developed quantitative structure-activity relationship (QSAR) models, to estimate K for PAHs, PCBs, DDx, and dioxin/furans for the two most common polymeric samplers, PDMS and LDPE.

View Article and Find Full Text PDF

Validation of a laboratory spray generation system and its use in a comparative study of hexamethylene diisocyanate (HDI) evaluation methods.

Environ Sci Process Impacts

November 2024

Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST), Qc, Canada.

Isocyanates are well-known irritants and sensitizers, and measuring their occupational airborne exposure is challenging due to their high chemical reactivity and semi-volatile nature. This study builds on a previous publication by our team that focused on comparing evaluation methods for isocyanates. The current research aims at developing, validating, and applying a laboratory generation system designed to replicate real-world conditions for spraying clear coats in autobody shops using hexamethylene diisocyanate (HDI)-based products.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!