A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Drug-eluting balloon: very short-term exposure and overlapping. | LitMetric

Paclitaxel balloon coating has shown promising effects in inhibiting restenosis in initial clinical trials. The aim of the present study was to evaluate the influence of two critical features of drug-eluting balloon (DEB) application - inflation time and increased dose due to overlapping balloons. Fifty-six stainless steel stents were implanted in the left anterior descending and circumflex coronary arteries of 28 domestic pigs using a 1.2:1.0 overstretch ratio. Stents were mounted on conventional uncoated and paclitaxel-coated angioplasty balloon catheters. The animals were randomized to five different treatments with a range of short (10 seconds [s] inflation using 1 DEB) to extended (2x60 s inflation using 2 DEB) intima contact time. After 28 days, quantitative angiography and histomorphometry of the stented arteries was performed on a total of 23 pigs. Paclitaxel balloon coating led to a marked reduction of parameters characterizing in-stent stenosis: Late lumen loss was 1.37 +/- 0.49 mm for uncoated balloons, 0.23 +/- 0.42 mm for one coated balloon 60 s inflation time, 0.37 +/- 0.28 mm for 10 s inflation time and 0.30 +/- 0.19 mm for the vessel segment treated by two coated balloons with 60 s inflation each. Neointimal areas were 4.26 +/- 1.18, 1.68 +/- 0.23, 1.83 +/- 0.40 and 1.67 +/- 0.46 mm(2), respectively (p = 0.001 versus control, p > 0.05 between paclitaxel-treated groups). Despite the marked reduction of neointimal proliferation, endothelialization of stent struts was present in all samples. DEB were found to effectively reduce neointimal proliferation regardless of inflation time and dose within the tested range. No adverse reactions were seen as dose was increased to more than three times the clinically tested dose.

Download full-text PDF

Source

Publication Analysis

Top Keywords

inflation time
16
drug-eluting balloon
8
paclitaxel balloon
8
balloon coating
8
inflation deb
8
marked reduction
8
+/-
8
neointimal proliferation
8
inflation
7
balloon
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!