A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Angular stable fixation of proximal humeral fractures. | LitMetric

Background: Proximal humeral fractures requiring surgical stabilization remain a therapeutic challenge. High rates of treatment-related complications have been reported to be associated, particularly in elderly patients with unstable fracture types and diminished bone quality. In recent years, angular stable implants have been introduced to improve the patients' outcome. The purpose of this study was to assess the clinical and radiographic long-term results after angular stable plate fixation of proximal humeral fractures at this Level I trauma center, with special emphasis on fracture healing, functional outcome and treatment related complications.

Methods: We retrospectively analyzed functional and radiographic results of 42 patients (average age: 57.8 years) after angular stable plate fixation of proximal humeral fractures at an average time of 3.2 (+/-0.8) years after trauma. Functional results were defined by the Constant shoulder score (CS) and the individual Constant score (CSindiv). Radiographic results were assessed by a three-view trauma series (anteroposterior, lateral, and axillary view). For operative treatment, two different angular stable implants were used. Twenty-seven patients were stabilized by a HOFER plate, fifteen patients by a Locking Proximal Humerus Plate.

Results: Clinical results revealed an average CS of 74.0 points and an average individual CSindiv of 79.2% points. Fourteen patients had an excellent functional outcome, eight patients a good outcome and fourteen patients had moderate functional results. Six patients (14%) had a poor outcome with less than 55% on CSindiv. Regarding the radiographic outcome, we had an overall union rate of 95% (40 of 42). Failures of reduction and fixation occurred in fourteen patients (33%), and in nine patients (21%) we had signs of a humeral head necrosis. Re-operation due to treatment-related complications was necessary in two patients (5%). Statistical analysis revealed that the fracture type and the age of the patients had a significant influence on the clinical outcome and on the incidence of treatment-related complications.

Conclusion: With regards to fracture healing and functional outcome of the patients, we had a satisfactory outcome after angular stable plate fixation of proximal humeral fractures. However, we experienced a notably high rate of technical failures and partial humeral head necrosis. Advanced surgical skills and experiences are necessary to achieve correct anatomic reduction and implant fixation, to reduce the risk of these treatment-related complications.

Download full-text PDF

Source
http://dx.doi.org/10.1097/TA.0b013e31815ede7bDOI Listing

Publication Analysis

Top Keywords

angular stable
24
proximal humeral
20
humeral fractures
20
fixation proximal
16
patients
13
treatment-related complications
12
stable plate
12
plate fixation
12
functional outcome
12
fourteen patients
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!