Purpose: To compare the results of staple versus locking compression plate fixation after closing wedge high tibial osteotomy.

Methods: A group of 23 patients (24 knees) who underwent box high tibial osteotomy and staple fixation was compared with another group of 19 patients (22 knees) who underwent a similar procedure but with locking compression plate fixation. Both groups were followed up for 3 years. The range of movement, Hospital for Special Surgery (HSS) Knee Score, time to full weight bearing, incidence of delayed union, femorotibial angle, and stage of osteoarthritis were compared.

Results: At 6 months after the operation, the median HSS score and the proportion of patients with excellent or good scores were significantly higher in the locking compression plate than the staple fixation group (76 vs 62, p=0.003; 75% vs 42%, p=0.0354), but not at one and 3 years. The range of movement was significantly greater in the locking compression plate fixation group in the short term (6 weeks, 3 and 6 months), but not after one year. The median time to full weight bearing was significantly shorter in the locking compression plate fixation group (86 vs 116 days, p<0.001). There were fewer delayed unions in the locking compression plate fixation group but not significantly (1 vs 5, p=0.198), possibly because of the small numbers involved. There was no difference, within the limits of measurement error, in the femorotibial angle or correction loss between the 2 groups.

Conclusion: Locking compression plate fixation obviates the use of plaster casts, enables early mobilisation and bone union, and reduces the numbers with delayed union and the time to full weight bearing. Longer-term studies are needed to evaluate its effect on revarisation and arthropathy.

Download full-text PDF

Source
http://dx.doi.org/10.1177/230949900801600307DOI Listing

Publication Analysis

Top Keywords

locking compression
24
compression plate
24
plate fixation
20
high tibial
12
fixation group
12
staple versus
8
versus locking
8
closing wedge
8
wedge high
8
tibial osteotomy
8

Similar Publications

A coherent optical frequency comb (OFC) with suppressed linewidth is demonstrated based on the spectral broadening of a directly modulated semiconductor microcavity laser with self-injection locking. Due to the high electro-optical response, the directly modulated microcavity laser provides a 10-GHz-spaced seeding OFC with 9 comb teeth in a 10 dB flatness window. Besides, an optical feedback fiber loop with two sub-loops is introduced to reduce the linewidth of the microlaser and suppress the undesired longitudinal modes.

View Article and Find Full Text PDF

We demonstrated what is believed to be the first 1.2 GHz nonlinear polarization rotation stretched-pulse mode-locked Yb:fiber laser with a compact design and innovative components. With a compact Faraday rotation angle has been used in NPR mode-locked lasers, and we find that incomplete isolation of backward-propagating light does not hinder self-starting.

View Article and Find Full Text PDF

Locking plates have a rapidly growing process especially in the past decades and results are satisfactory especially in the osteoporotic bones compared to non-locking compression plates. There are many forms of failure in the fracture fixation of locking plates, and screw pull-out is one of the main failure reasons. In this study, we aim to investigate pull-out failure in locking plates using locking spongious screws.

View Article and Find Full Text PDF

Objective:  To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.

Study Design:  Six, 13-hole, 3.

View Article and Find Full Text PDF

Mandibular Reconstruction With a Patient-Specific Implant Following Surgical Excision of an Acanthomatous Ameloblastoma in a Dog.

J Vet Dent

January 2025

Department of Dentistry, Oral and Maxillo-facial Surgery, Eastcott Veterinary Referrals, Part of Linnaeus Group, Swindon, UK.

Canine acanthomatous ameloblastoma (CAA) is an invasive benign epithelial odontogenic tumour most commonly affecting the mandible of large breed dogs. To the author's knowledge, this report describes the first computer-aided design patient-specific implant (PSI) that has been placed for a critical sized bone defect in mandibular reconstruction of a dog in the UK. The aim was to restore mandibular stability using a regenerative approach combining a titanium locking plate and compression-resistant matrix infused with recombinant human bone morphogenetic protein-2 (rhBMP-2) to bridge the 85 mm mandibular defect created by a segmental mandibulectomy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!