A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ablation of bull prostate using novel bipolar radiofrequency ablation probe. | LitMetric

Purpose: We describe the use of a novel bipolar radiofrequency (RF) system for the destruction of prostate tissue in an ex vivo model.

Materials And Methods: A bipolar RF delivery system (Trod Medical, France) was linked to a 500 kHz generator. Eight lesions were created in an ex vivo bull prostate model using 7-mm (n = 4) and 10-mm probes (n = 4). Ablation was performed for 150 seconds. Temperature was recorded at the center of the lesion (Tc) and at the periphery (Tp) of the prostate. Tissue damage, both within and without the intended destruction zones, was assessed. The distance from Tc to Tp was recorded.

Results: All lesions created with either the 7-mm or 10-mm bipolar RF ablation (RFA) probes demonstrated complete tissue destruction only within the intended zone. Using the 7-mm probe, the mean Tc was 82 degrees C and the mean Tp 34 degrees C. The mean distance from the edge of the lesion to the periphery was 5 mm. Impedance was 62 Ohm, and power was 4 watts during ablation with the 7-mm probe. With the 10-mm probe, the mean Tc and Tp were 70 degrees C and 41 degrees C, respectively. The mean distance from the edge of the lesion to the periphery was 5 mm. Impedance was 78 Ohm, and power was 4.5 watts during ablation with the 10-mm probe.

Conclusions: In an ex vivo model, bipolar RFA is capable of producing lesions with precise margins. Spread of heat is limited, evidenced histologically and by significant temperature drop off. This technology holds promise in the management of benign and malignant urologic diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2008.0105DOI Listing

Publication Analysis

Top Keywords

lesion periphery
12
bull prostate
8
novel bipolar
8
bipolar radiofrequency
8
prostate tissue
8
lesions created
8
7-mm 10-mm
8
7-mm probe
8
probe degrees
8
degrees degrees
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!