[Research on calibration transfer of NIR filter spectrophotometer].

Guang Pu Xue Yu Guang Pu Fen Xi

School of Information Science and Technology, Xiamen University, Xiamen 361005, China.

Published: October 2008

Calibration transfer is an important issue to building up universal and comparable performance of spectrometer data in near infrared spectral analysis technology. Methods of slope/bias correction, direct standardization (DS), and target factor analysis (TFA) were used for the calibration transfer among five NIR filter spectrophotometers using maize as the samples. The effects of three calibration transfer methods were compared. The DS method has the best performance. The average calibration transfer difference of DS is 7.01%. This study also relates to the dependence of calibration transfer on the number of standardization samples. It was proven by experiment that the results of calibration transfer will be better as the number of samples is increased and will be generally stable when there are twenty standardization samples. However, the effect of calibration transfer attained by DS is degraded sharply when the number of standardization samples decreases to be below twenty. Moreover, slope/bias and TFA are not sensitive to the number of standardization samples.

Download full-text PDF

Source

Publication Analysis

Top Keywords

calibration transfer
32
standardization samples
16
number standardization
12
transfer
8
transfer nir
8
nir filter
8
calibration
7
samples
6
standardization
5
[research calibration
4

Similar Publications

Unlabelled: Accurate prediction of moisture distributions in wood is among the most critical challenges in timber engineering. Achieving this requires a well-coordinated comparison of experimental methods and simulation tools. While significant progress has been made in developing simulation tools in recent years, a lack of experience with and trust in these tools continues to hinder broader implementation, especially when it comes to free water and its absorption.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

rGO/HfO nanocomposite-enabled electrochemical sensor for high-performance pesticide detection.

Talanta

January 2025

Department of Chemical and Biomolecular Engineering, University of Connecticut, CT, 06269, United States. Electronic address:

This study applies a periodic table-guided approach to select and investigate hafnium oxide (HfO), in conjunction with reduced graphene oxide (rGO), for the electrochemical determination of methyl parathion (MP), an organophosphate insecticide. MP poses significant ecological and health risks due to its high toxicity, and despite bans, illegal use has been reported, especially in the global south. To address these challenges, an electrode modified with a nanocomposite of rGO/HfO was first constructed for MP detection.

View Article and Find Full Text PDF

Plug-and-play myoelectric control via a self-calibrating random forest common model.

J Neural Eng

January 2025

School of Informatics, The University of Edinburgh, 10 Chricton Street, Edinburgh, EH8 9LE, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND.

Objective: Electromyographic (EMG) signals show large variabilities over time due to factors such as electrode shifting, user behaviour variations, etc., substantially degrading the performance of myoelectric control models in long-term use. Previously one-time model calibration was usually required each time before usage.

View Article and Find Full Text PDF

A cycle-based model to predict no usable blastocyst formation following cycles of in vitro fertilization in patients with normal ovarian reserve.

Reprod Biol Endocrinol

January 2025

Department of Reproductive Medicine Center, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Zhengzhou, The People's Republic of China.

Objective: This study aimed to develop a predictive model for the risk of no usable blastocyst formation in patients with normal ovarian reserve undergoing IVF.

Methods: The model was derived from 7,901 patients who underwent their first oocyte retrieval and subsequent blastocyst culture, of which 446 cases have no usable blastocysts formed. Univariate regression analyses, least absolute shrinkage and selection operator regression analysis were used to identify the association of patient and cycle characteristics with the presence of no available blastocyst and to create a nomogram.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!