A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new electrocautery pleural biopsy technique using an insulated-tip diathermic knife during semirigid pleuroscopy. | LitMetric

Background: The biopsy size obtained with standard flexible forceps (SFF) during semirigid pleuroscopy is often insufficient for pathological examination. An insulated-tip diathermic knife (IT knife) allows safe resection of a larger lesion during gastrointestinal endoscopy. We sought to validate an electrocautery pleural biopsy technique using the IT knife during semirigid pleuroscopy. We compared the diagnosis of specimens obtained using the IT knife and SFF in 20 subjects with unexplained pleural effusion, and reviewed pleuroscopic parameters such as complications, procedure time, and diameter of the specimens.

Methods: After injecting saline with lidocaine and epinephrine below the affected pleura, the lesion was incised in a circular shape with full thickness by manipulating the IT knife.

Results: Diagnostic yields from specimens obtained with the IT knife and SFF were 85% (17 of 20 cases) and 60% (12 of 20 cases), respectively. The IT knife biopsy was superior to SFF in 8 of 20 patients (malignant pleural mesothelioma in three, nonspecific inflammation in two, metastatic breast cancer in one, and tuberculosis in one). These pleural lesions revealed thickened, smooth abnormal appearances. The overall diagnostic yield for both IT knife and SFF was 100%. Median time of the procedure, from first pleural injection to specimen removal, was 21 min (range 12-92 min), and median diameter of specimen was 13 mm (range 6-23 mm). There were no severe complications during the procedure.

Conclusions: Electrocautery biopsy using the IT knife during semirigid pleuroscopy has great potential for diagnosing smooth abnormal pleura which are difficult to biopsy with SFF.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-008-0263-8DOI Listing

Publication Analysis

Top Keywords

semirigid pleuroscopy
16
knife semirigid
12
knife sff
12
knife
9
electrocautery pleural
8
pleural biopsy
8
biopsy technique
8
insulated-tip diathermic
8
diathermic knife
8
specimens knife
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!