A procedure based on liquid chromatography-electrospray ionization mass spectrometry is described for determination of methylphenidate (MPH) and its principal metabolite ritalinic acid (RA) in plasma, urine, oral fluid and sweat using 3,4-methylendioxypropylamphetamine (MDPA) as internal standard. Aliquots of 100microL biological fluids and sweat patch were initially treated with acetonitrile, centrifuged, and clear supernatants evaporated and redissolved in 10mM ammonium acetate. Chromatography was performed on a reversed-phase column using a gradient of 10mM ammonium acetate and acetonitrile as a mobile phase at a flow rate of 1mL/min. Separated analytes were confirmed and quantified by positive electrospray ionization mass spectrometry and selected ion monitoring acquisition mode. Limits of quantifications were 1ng/mL plasma, 1ng/sweat patch, 0.5ng/mL oral fluid and urine for MHF; 1ng/mL plasma and oral fluid, 1ng/sweat patch, 0.5ng/mL urine for RA using 100microL biological fluids or one sweat-patch per assay. Calibration curves were linear over the calibration ranges for both MPH and RA, with r(2)>0.99. At three concentrations spanning the linear dynamic range of the assay, mean recoveries ranged between 67.9-90.3% for MPH and 36.3-92.4% for RA in the different biological matrices. This method was applied to therapeutic monitoring of MHP and RA in conventional and non-conventional biological matrices from individuals in drug treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2008.11.020DOI Listing

Publication Analysis

Top Keywords

ionization mass
12
mass spectrometry
12
biological matrices
12
oral fluid
12
liquid chromatography-electrospray
8
chromatography-electrospray ionization
8
determination methylphenidate
8
ritalinic acid
8
conventional non-conventional
8
non-conventional biological
8

Similar Publications

We report a bithiophene-based fluorescence probe BDT (2,2'-(((1 E, 1'E)-[2,2'-bithiophene]-5,5'-diylbis(methaneylylidene))bis(azaneylylidene))bis(4-(tert-butyl)phenol)) for recognizing ClO. BDT selectively responded to ClO, leading to a blue fluorescence enhancement in a mixture of DMF/HEPES buffer (9:1, v/v). Importantly, BDT showed an ultrafast response (within 1 s) to ClO among the fluorescent turn-on chemosensors based on bithiophene.

View Article and Find Full Text PDF

Rapid Determination of Organic and Inorganic Selenium in Poultry Tissues by Internal Extractive Electrospray Ionization Mass Spectrometry.

Anal Chem

January 2025

The Jiangxi Province Key Laboratory for Diagnosis, Treatment, and Rehabilitation of cancer in Chinese Medicine, Jiangxi University of Chinese Medicine, Nanchang 330004, P. R. China.

An online reactive internal extraction electrospray ionization (iEESI) method was developed for the rapid determination of organic and inorganic speciation information for selenium in poultry tissue samples without complex sample pretreatment. The addition of citric acid as a reducing agent to the internal extraction solvent of methanol/acetic acid (99:1, V/V) for iEESI resulted in the reduction of selenate in the sample to selenite, accompanied by the production of malic acid as an oxidation product. The quantitative analysis of selenate was conducted by using malic acid.

View Article and Find Full Text PDF

This study systematically investigated the effect of organic solvent addition on the detection signal intensity of 15 organic pesticides in water using ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS). The analysis of chromatographic peak area ratios in ultrapure water (UPW) versus 30% methanol (MeOH)-UPW showed that the adsorption effects (AEs, mainly from injection vials with weaker polarity) were the main factor influencing the detection intensity of the organic pesticides. The AEs varied with pesticide type and concentration, especially for those with high logK values and longer retention times, such as malathion, triadimefon, prometryn, S-metolachlor, diazinon, and profenofos.

View Article and Find Full Text PDF

Bisphenols may negatively impact human health. In this study, we propose the use of HPLC-FLD for the simultaneous determination of bisphenols in pericardial fluid samples collected from patients with coronary artery disease undergoing coronary artery bypass surgery. For sample preparation, a fast, simple, and "green" DLLME method was used, achieving mean recovery values in the range of 62%-98% with relative standard deviations between 2% and 6% for all analytes.

View Article and Find Full Text PDF

New Triterpenoids from the Leaves of and Their Anti-Inflammatory Activity.

Molecules

December 2024

Guangxi Key Laboratory of Green Chemical Materials and Safety Technology, College of Petroleum and Chemical Engineering, Beibu Gulf University, Qinzhou 535000, China.

Six new triterpenoids, heritieras C-H (-), along with thirteen known triterpenoids (-), were isolated from the leaves of . Their structures were identified by spectroscopic analysis, including 1D and 2D nuclear magnetic resonance (NMR), high-resolution electrospray ionization mass spectrometry (HRESIMS), and by comparison with the literature. Anti-inflammatory activity of the isolates was evaluated using the lipopolysaccharide (LPS) stimulated RAW 264.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!