A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Use of allogenous material in the management of spina bifida aperta]. | LitMetric

[Use of allogenous material in the management of spina bifida aperta].

Rozhl Chir

Klinika detskej chirurgie DFNsP a LF UKo, Bratislava, Slovenská republika.

Published: October 2008

Aim: "Conditio sine qua non" in the management of open neural tube defects includes closure of all layers with as minimum as possible tension left within the suture region, in order to prevent early, as well as long-term postoperative complications. In extensive fascial defects, the authors used the Gore-Tex patch as an alternative to myofascial or fasciocutaneous flaps.

Patients And Methods: From January 2004 to January 2008, 23 patients suffering from open spina bifida underwent surgery in the Bratislava Pediatric Surgery Centre. In 17 subjects, the fascia was sutured following a myofascial release, in 2 subjects the suture was secured with tissue adhesive. In 4 subjects, the Gore-Tex patch was implanted to secure the "tension free" plasty; the Gore-Tex Dual Mesh was used in 2 subjects as well as the Gore-Tex Spinal.

Results: Two subjects, who had the Gore-Tex Dual Mesh implanted, developed sequestration of the implant during the late postopertive period. Upon reoperation, the authors removed the Gore-Tex Dual Mesh in the both subjects. However, they found a firm fibrous membrane, which was considered sufficient to protect the dural sac. On the contrary, the both subjects who had the Gore-Tex Spinal implanted, healed with no complications recorded.

Conclusion: Based on the experience, the Gore-Tex Dual Mesh, although implanted lege artis, does not appear a suitable material for fascia replacements in open spina bifida plastic procedures. Further experience will give more evidence, whether Gore-Tex Spinal would be a suitable alternative, however, the courses in the 2 subjects have hitherto been encouraging.

Download full-text PDF

Source

Publication Analysis

Top Keywords

gore-tex dual
16
dual mesh
16
spina bifida
12
subjects gore-tex
12
gore-tex
9
gore-tex patch
8
open spina
8
subjects
8
mesh subjects
8
mesh implanted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!