Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Conventional Doppler ultrasound (US) investigations are limited to detect only the axial component of the blood velocity vector. A novel dual-beam method has been recently proposed in which the Doppler angle is estimated through a reference US beam, and the velocity magnitude through a measuring US beam, respectively. In this study, the performance of such a method has been assessed quantitatively through in vitro and in vivo measurements made in different experimental conditions. In vitro, more than 300 acquisitions were completed using seven transducers to insonify a straight tube phantom at different Doppler angles. In steady laminar flow conditions, the velocity magnitude was measured with mean error of -1.9% (95% confidence interval: -2.33% to -1.47%) and standard deviation of 3.4%, with respect to a reference velocity. In pulsatile flow conditions, reproducibility tests of the entire velocity waveforms provided an average coefficient of variation (CV) of 6.9%. For peak velocity measurements made at five Doppler angles and three flow rates, the intrasession and intersession CVs were in the range 0.8-3.7% and 2.9-10.6%, respectively. The peak systolic velocities (PSVs) in the common carotid arteries of 21 volunteers were estimated with 95% limits of agreement of +/- 9.6 cm/s (intersession). This analysis shows that the proposed dual-beam method is capable of overcoming the Doppler angle ambiguity by producing reliable velocity measurements over a large set of experimental conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2008.10.012 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!