A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of pyrethroids from pesticide residues in porcine muscle and pasteurized milk using GC. | LitMetric

The principal goal of this work was to develop an efficient method for the simultaneous determination of four pyrethroid (PYR) insecticides, cyfluthrin, cyhalothrin, cypermethrin, and deltamethrin, in porcine muscle and pasteurized milk using liquid-liquid extraction (LLE). Sample extraction was carried out with and without additional column cleanup procedures, and the final determination was made using GC with electron-capture detector (ECD). The pesticide identity was confirmed using GC-MS in the SIM mode. Since there were minor differences between the extraction procedures, extraction without the additional cleanup procedure was used throughout the work. The method was validated by fortifying blank samples with half, two, and four times the maximum residue limit (MRL) of each PYR. The average recoveries (n = 6) ranged from 83.5 to 99.2% and 82.9 to 109% in porcine muscle and pasteurized milk, respectively. The repeatability of measurements expressed as RSDs, was in the range of 1.7-11.9 and 1.5-10.3% in porcine muscle and pasteurized milk, respectively. The LODs ranged from 3.3 to 9 and 3 to 8.1 ppm, whereas the LOQs ranged from 10 to 27.4 and 9 to 24.6 ppm, in porcine muscle and pasteurized milk, respectively. The applicability of the method was demonstrated by analyzing real samples collected from major cities in the Republic of Korea. No residues of the selected pesticides were detected in any of the samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200800481DOI Listing

Publication Analysis

Top Keywords

porcine muscle
20
muscle pasteurized
20
pasteurized milk
20
simultaneous determination
8
porcine
5
muscle
5
pasteurized
5
milk
5
determination pyrethroids
4
pyrethroids pesticide
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!