This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-008-1253-x | DOI Listing |
Eur J Vasc Endovasc Surg
January 2025
German Aortic Centre, Department of Vascular Medicine, University Heart and Vascular Centre UKE Hamburg, Hamburg, Germany.
Objective: Half of re-interventions after fenestrated and branched endovascular aortic repair (FB-EVAR) are target vessel related. Regarding bridging stent choice, existing data are controversial. This meta-analysis aimed to evaluate the performance of Advanta V12/iCAST as bridging stent in FB-EVAR.
View Article and Find Full Text PDFJ Vasc Surg
January 2025
Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS Sant'Orsola, Bologna, Italy.
Introduction/aim: The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA: <25mm) or severely angulated (APA: >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT.
Methods: All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook-Medical, Bloomington, IN, US) and PDT from 2021 to 2023 were analyzed.
J Clin Med
December 2024
Department of Vascular Surgery and Transplantation, Medical University of Bialystok, 15-276 Bialystok, Poland.
Stent-graft implantation is a widely recognized method for endovascular treatment of aortic aneurysms. In cases where the aneurysm involves the thoracic and abdominal aorta, repair including fenestrated and branched stent grafts provides a viable alternative. This approach, initially reserved for patients unsuitable for open surgery, has become preferred for anatomically appropriate thoracoabdominal aortic aneurysms.
View Article and Find Full Text PDFEur J Vasc Endovasc Surg
December 2024
Division of Vascular Surgery, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden.
Objective: Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting.
View Article and Find Full Text PDFJ Endovasc Ther
November 2024
Department of Vascular Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, P. R. China.
Purpose: This study aims to summarize the experience and outcomes of using 3D printing technology to assist physician-modified fenestrated-branched endovascular aortic repair (PM-FBEVAR) in the treatment of thoracoabdominal aortic dissection involving visceral branches.
Materials And Methods: From December 2018 to May 2023, clinical data of 48 consecutive patients (35 males; mean age, 62.9±11.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!