Membrane optode for mercury(II) determination in aqueous samples.

J Hazard Mater

Department of Environmental Sciences, S.V. University, Tirupati 517502, India.

Published: July 2009

A color changeable optode for Hg(II) was prepared by the immobilization of a dye 4-(2-pyridylazo)resorcinol (PAR) and a liquid ion-exchanger trioctylmethylammonium chloride (Aliquat-336) in the tri-(2-ethylhexyl) phosphate plasticized cellulose triacetate matrix. Hg(II) and CH(3)Hg(+) from aqueous samples could be quantitatively preconcentrated in this transparent optode producing a distinct color change (lambda(max)=520 nm) within 5 min equilibration time in bicarbonate aqueous medium or 30 min in natural water. Whereas optode sample without Aliquat-336 did not change its color corresponding to Hg-PAR complex on equilibrium with the same aqueous solution containing Hg(II) ions. The uptake of Hg(II) was found to be pH dependent with a maximum (>90%) at a pH 7.5. The uptake of ions like Cu(II), Fe(II), Zn(II) and Pb(II) was negligible in the optode where as the uptake of Cd(II) and Zn(II) ions was 10-15% at pH 7.5. The optode developed in the present work was studied for its analytical application for Hg(II) in the aqueous samples by spectrophotometry, radiotracer ((203)Hg), Energy Dispersive X-ray Fluorescence (EDXRF) analyses and Instrumental Neutron Activation Analysis (INAA). The minimum amount of Hg(II) required to produce detectable response by spectrophotometry, INAA and EDXRF were found to be 5.5, 1 and 12 microg, respectively. This optode showed a linear increase in the absorbance at lambda(max)=520 nm over a concentration range of 0.22-1.32 microg/mL of Hg(II) ions in aqueous solution for 5 min. The preconcentration of Hg(II) from large volume of aqueous solution was used to extend the lower limit of concentration range that can be quantified by the spectrophotometry of optode. It was observed that preconcentration of 11 microg Hg(II) in 100mL (0.11 microg/mL) in aqueous samples gives a distinct color change and absorbance above 3 sigma of the blank absorbance. The optode developed in the present work was found to be reusable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2008.11.027DOI Listing

Publication Analysis

Top Keywords

aqueous samples
16
aqueous solution
12
hgii
9
aqueous
8
optode
8
distinct color
8
color change
8
hgii ions
8
optode developed
8
developed work
8

Similar Publications

Rapid identification of pathogenic bacteria from clinical positive blood cultures virus-like magnetic bead enrichment and MALDI-TOF MS profiling.

Analyst

January 2025

Institutes of Biomedical Sciences & Shanghai Stomatological Hospital, Department of Chemistry, Fudan University, Shanghai 200433, China.

Reducing the time required for the detection of bacteria in blood samples is a critical area of investigation in the field of clinical diagnosis. Positive blood culture samples often require a plate culture stage due to the interference of blood cells and proteins, which can result in significant delays before the isolation of single colonies suitable for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis. In this study, we developed a non-specific enrichment strategy based on SiO-encapsulated FeO nanoparticles combined with MALDI-TOF MS for direct identification of bacteria from aqueous environments or positive blood culture samples.

View Article and Find Full Text PDF

Bilirubin (BR) is the product of cellular heme catabolism and the main bile pigment in animal blood. It is an established biomarker for hemolysis and liver function. Over the last decade, mild hyperbilirubinemia has been shown to be a biomarker for a lower risk of cardiovascular disease, due to its antioxidant and anti-inflammatory effects.

View Article and Find Full Text PDF

RP-HPLC Method for Rhein Quantification in L. (Fabaceae) Leaves.

Acta Med Philipp

December 2024

Institute of Herbal Medicine, National Institutes of Health, University of the Philippines Manila.

Objectives: The aim of this study is to establish a Reversed Phase - High Performance Liquid Chromatographic (RP-HPLC) method for the quantification of Rhein from L. leaves.

Methods: A Shimadzu system equipped with a C18 Column (150 x 4.

View Article and Find Full Text PDF

This study investigated the adsorptive properties of functionalized fabric containing dimethylaminomethyl calix[4]arene (DMAM-Calix) to remove anionic methyl orange (MO) and cationic Rhodamine B (RhB) dyes in aqueous media. Adsorption studies were performed using a filtration system packed with DMAM-Calix-functionalized fabric (). The results revealed that the cationic and anionic structures work compatibly in a binary mixture medium.

View Article and Find Full Text PDF

The sensitive Bisphenol A (BPA) detection by an electrochemical sensor based on gold nanoparticle-doped molecularly imprinted polymer was successfully improved. This study describes the development of a method for BPA detection in both aqueous solution and real water samples using N-methacroyl-(L)-cysteine methyl ester and N-methacryloyl-(L)-phenylalanine methyl ester coated pencil graphite electrodes modified with AuNPs by differential pulse voltammetry (DPV). Importantly, AuNPs, which increase the electroactivity, were used to increase the surface area of a BPA-imprinted pencil graphite electrode (MIP PGE) sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!