Efficacy of spinal implant removal after thoracolumbar junction fusion.

J Korean Neurosurg Soc

Department of Neurosurgery, College of Medicine, Chosun University, Gwangju, Korea.

Published: March 2008

Objective: The purpose of this study was to evaluate the efficacy of spinal implant removal and to determine the possible mechanisms of pain relief.

Methods: Fourteen patients with an average of 42 years (from 22 to 67 years) were retrospectively evaluated. All patients had posterior spinal instrumentation and fusion, who later developed recurrent back pain or persistent back pain despite a solid fusion mass. Patients' clinical charts, operative notes, and preoperative x-rays were evaluated. Relief of pain was evaluated by the Visual Analog Scale (VAS) pain change after implant removal. Clinical outcome using VAS and modified MacNab's criteria was assessed on before implant removal, 1 month after implant removal and at the last clinical follow-up. Radiological analysis of sagittal alignment was also assessed.

Results: Average follow-up period was 18 months (from 12 to 25 months). There were 4 patients who had persistent back pain at the surgical site and 10 patients who had recurrent back pain. The median time after the first fusion operation and the recurrence of pain was 6.5 months (from 3 to 13 months). All patients except one had palpation pain at operative site. The mean blood loss was less than 100ml and there were no major complications. The mean pain score before screw removal and at final follow up was 6.4 and 2.9, respectively (p<0.005). Thirteen of the 14 patients were graded as excellent and good according to modified MacNab's criteria. Overall 5.9 degrees of sagittal correction loss was observed at final follow up, but was not statistically significant.

Conclusion: For the patients with persistent or recurrent back pain after spinal instrumentation, removal of the spinal implant may be safe and an efficient procedure for carefully selected patients who have palpation pain and are unresponsive to conservative treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2588244PMC
http://dx.doi.org/10.3340/jkns.2008.43.3.139DOI Listing

Publication Analysis

Top Keywords

implant removal
20
pain
10
efficacy spinal
8
spinal implant
8
recurrent pain
8
persistent pain
8
removal clinical
8
months months
8
months patients
8
removal
6

Similar Publications

Objective: To analyze data from patient information forms (PIFs) submitted to the manufacturer of a new 3-piece inflatable penile prosthesis (IPP), the Rigicon Infla10® , to summarize interim outcomes of 250 implantations in a single center, which is the largest series in Türkiye.

Methods: A retrospective review of PIFs from 250 patients implanted with the IPP between January 2021 and December 2023 was performed to assess patient characteristics, surgical data, device durability, patient satisfaction, and rates of reoperation for any reason.

Results: The mean ± SD (range) follow-up was 21.

View Article and Find Full Text PDF

Background/purpose: Inferior alveolar nerve (IAN) injury is the most serious complication associated with dental implant surgery, posing difficulties in treatment and potential for permanent disabilities. This study aimed to identify patient-related risk factors for IAN injury during implant placement and to investigate sensory disturbances depending on whether the implant was removed.

Materials And Methods: Twenty-eight patients with implant-related IAN injury were included.

View Article and Find Full Text PDF

Microplastics (MPs) have been detected in various environmental matrices, drinking water, and food, and their presence is an ecological and human health concern. Most research on MPs has focused solely on their detection and analysis. However, sample pretreatment methods are critical for accurate MP analysis and must be properly established.

View Article and Find Full Text PDF

Background: Revision reverse total shoulder arthroplasty (rTSA) of a previously cemented humeral component is challenging. In hip arthroplasty, the cement-within-cement (CwC) technique has been well described as an effective option. However, for shoulder arthroplasty there remains a paucity of data investigating this technique.

View Article and Find Full Text PDF

CellREADR: An ADAR-based RNA sensor-actuator device.

Methods Enzymol

January 2025

Department of Neurobiology, Duke University School of Medicine, Durham, NC, United States; Department of Biomedical Engineering, Duke University, Durham, NC, United States. Electronic address:

RNAs are central mediators of genetic information flow and gene regulation that underlie diverse cell types and cell states across species. Thus, methods that can sense and respond to RNA profiles in living cells will have broad applications in biology and medicine. CellREADR - Cell access through RNA sensing by Endogenous ADAR (adenosine deaminase acting on RNA), is a programmable RNA sensor-actuator technology that couples the detection of a cell-defining RNA to the translation of an effector protein to monitor and manipulate the cell.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!