Knoop hardness depth profile of polyacid-modified composite resins.

Quintessence Int

Department of Paediatric Dentistry, PaeCaMeD, School of Dentistry, Ghent University, Gent, Belgium.

Published: October 2008

AI Article Synopsis

Article Abstract

Objectives: To determine the hardness versus depth profile of several polyacid-modified composite resins (PAM-Cs) as a function of shade (A2, A4) and compare the depth of cure (DoC) based on these profiles with that previously obtained with the scraping and penetrometer methods.

Method And Materials: Samples of 6 PAM-Cs (Hytac, 3M ESPE; F2000, 3M ESPE; Glasiosite, Voco; Dyract, Dentsply DeTrey; Dyract AP, Dentsply DeTrey; Compoglass F, Vivadent) and 3 composite resins (Herculite Enamel XRV, Kerr; Z100, 3M ESPE; Durafill VS, Heraeus Kulzer) with shades A2 and A4 were light-cured in bulk in split stainless steel molds (thickness ranging from 0.5 to 3.5 mm in steps of 0.5 mm). The Knoop hardness of the irradiated top (KHN(surface)) and nonirradiated bottom (KHN(bottom)) surfaces was determined as a function of sample thickness using a microhardness tester.

Results: Regression analysis demonstrated that for a given material, KHN(bottom) equals KHN(surface) up to a specific depth (= DoC) depending on the material and shade and then decreases linearly with increasing depth. The decrease of the KHN per unit depth differs significantly among materials and shades. According to a regression analysis, the scraping and penetrometer methods overestimate the DoC of PAM-Cs compared to the method based on the change of the hardness indentation with depth.

Conclusions: Shade A2 results in greater values of DoC than shade A4, the effect depending quantitatively on the formulation of the material. Some formulations of PAM-Cs do not reach a DoC of 2 mm, a layer recommended to be applied in the incremental technique. The DoC as determined according to ISO 4049:2000 apparently is based on a lower degree of polymerization corresponding to a KHN of 80% of the irradiated surface.

Download full-text PDF

Source

Publication Analysis

Top Keywords

composite resins
12
knoop hardness
8
depth profile
8
profile polyacid-modified
8
polyacid-modified composite
8
scraping penetrometer
8
dyract dentsply
8
dentsply detrey
8
regression analysis
8
depth
6

Similar Publications

The role of aging and various surface preparation methods in the repair of nanohybrid composites.

BMC Oral Health

January 2025

Faculty of Dentistry, Department of Restorative Dentistry, Gazi University, Bişkek St. 1. St. Number: 8 Emek, Ankara, Turkey.

Background: Repairing composite resins is a less invasive alternative to complete restoration replacement. To achieve a successful bond between the existing and newly applied composite materials, various surface preparation methods, such as sandblasting and acid etching, have been explored. The aim of the study was to evaluate the effect of different surface treatments on the repair bond strength of a universal nanohybrid composite resin restorative material before and after thermal aging, by utilizing a micro-shear bond strength (µSBS) test.

View Article and Find Full Text PDF

The emergence of toothpastes containing different abrasive and whitening substances has been a constant concern among dental professionals. The aim of the present study was to perform an in vitro assessment of the surface topography of nanoparticle composite resins subjected to simulated brushing with dentifrices. Test samples were prepared with Filtek Universal (3M ESPE), Filtek Bulkfill (3M ESPE) and Z350 (3M ESPE), with 24 samples per resin.

View Article and Find Full Text PDF

HEMA-free versus HEMA-containing adhesive systems: a systematic review.

Syst Rev

January 2025

Conservative Dentistry Department, Faculty of Dentistry, Mansoura University, Mansoura, Postal Code, 35516, Egypt.

Background: Hydrophilic monomer 2-hydroxyethyl methacrylate (HEMA)-free adhesive systems are gaining increasing popularity nowadays. Although the addition of HEMA to dental adhesives improves dentin wettability and resin diffusion into demineralized collagen fibrils, HEMA's high hydrophilicity can lead to hydrolytic degradation of the adhesive interface. Thus, HEMA-free adhesive systems have been developed.

View Article and Find Full Text PDF

Direct resin restoration has been widely used to restore the tooth defect for its convenience and minimal invasion. However, the accuracy of the final contour of class II restoration is often unpredictable and quite technique-sensitive due to the limitation of traditional matrix band system. In this study, the authors developed a novel matrix band system using shape memory polymer (SMP), which possessed two reversible shapes including digitized permanent shape to reproduce anatomical proximal contour and programmable temporary shape for clinical practice and reservation.

View Article and Find Full Text PDF

Objective: To investigate the effects of bulk-fill, resin-based composite types (high or low viscosity) on the internal adaptation of Class V restorations.

Study Design: Experimental study. Place and Duration of the Study: Hefei Stomatological Hospital, Hefei, China, from October 2022 to December 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!