A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precision and reliability of strength (Jamar vs. Biodex handgrip) and body composition (dual-energy X-ray absorptiometry vs. bioimpedance analysis) measurements in advanced cancer patients. | LitMetric

Important deteriorations in body composition and strength occur and need to be accurately measured in advanced cancer patients (ACPs). The aim of this study was to establish the relationship between a single-frequency bioimpedance analyzer (BIA) and the dual-energy X-ray absorptiometer (DXA), as well as the Jamar handgrip dynometer and the Biodex handgrip attachment, and to determine the precision of each of these instruments in ACPs. Eighty-one ACPs with non-small-cell lung cancer and gastrointestinal cancer were recruited from the McGill University Health Centre (Montreal, Que.). Consecutive paired measurements, with repositioning between measurements, were obtained for total-body DXA, BIA, Biodex handgrip, and BIA plus Jamar handgrip. The total-body percent coefficient of variation (%CV) for the BIA and DXA were 1.34 and 1.56 for fat mass (FM), respectively, and 0.42 and 0.72 for fat free mass (FFM), respectively. The %CV for the Jamar and Biodex handgrips were 6.3 and 16.7, respectively. Bland-Altman plots were used to characterize the limits of agreement between DXA and BIA for FM (4.60 +/- 7.80 (-3.19 to 12.39) kg) and FFM (-1.87 +/- 7.16 (-9.03 to 5.29) kg). Both DXA and BIA demonstrate good short-term precision in ACPs. However, given its poor accuracy, it remains to be determined if BIA can be used to monitor ACPs for changes in total-body tissue composition as a function of time, whether for observation or response to treatment. Furthermore, because of wide limits of agreement, the DXA and BIA cannot be used interchangeably in research or clinical settings. The Jamar handgrip dynamometer shows more consistency than the Biodex handgrip attachment in ACPs, and should therefore be the preferred measure of changes in strength over time.

Download full-text PDF

Source
http://dx.doi.org/10.1139/H08-122DOI Listing

Publication Analysis

Top Keywords

biodex handgrip
16
dxa bia
16
jamar handgrip
12
jamar biodex
8
body composition
8
dual-energy x-ray
8
advanced cancer
8
cancer patients
8
bia
8
handgrip attachment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!