The LMA Supreme is a new extraglottic airway device which brings together features of the LMA ProSeal, Fastrach and Unique. We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal and the LMA Supreme in paralysed anesthetised patients. Ninety-three females aged 19-71 years were studied. Both devices were inserted into each patient in random order. Two attempts were allowed. Digital insertion was used for the first attempt and guided insertion for the second attempt. Oropharyngeal leak pressure and fibreoptic position were determined during cuff inflation from 0 to 40 ml in 10 ml increments. Gastric tube insertion was attempted if there was no gas leak from the drain tube. First attempt and overall insertion success were similar (LMA ProSeal, 92% and 100%; LMA Supreme 95% and 100%). Guided insertion was always successful following failed digital insertion. Oropharyngeal leak pressure was 4-8 ml higher for the LMA ProSeal over the inflation range (p < 0.001). Intracuff pressure was 16-35 cm higher for the LMA ProSeal when the cuff volume was 20-40 ml (p < 0.001). There was an increase in oropharyngeal leak pressure with increasing cuff volume from 10 to 30 ml for both devices, but no change from 0 to 10 ml and 30-40 ml. There were no differences in the fibreoptic position of the airway or drain tube. The first attempt and overall insertion success for the gastric tube was similar (LMA ProSeal 91% and 100%; LMA Supreme 92% and 100%). We conclude that ease of insertion, gastric tube placement and fibreoptic position are similar for the LMA ProSeal and LMA Supreme in paralysed, anaesthetised females, but oropharyngeal leak pressure and intracuff pressure are higher for the LMA ProSeal.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1365-2044.2008.05682.x | DOI Listing |
Int J Surg Case Rep
November 2024
Department of Anesthesiology, The Affiliated Cancer Hospital of Nanjing Medical University, Jiangsu Cancer Hospital & Jiangsu Institute of Cancer Research, 210009 Nanjing, China.. Electronic address:
Introduction And Importance: Arytenoid dislocation, typically manifested as hoarseness and coughing when drinking, is a rare perioperative scenario, with an incidence rate of 0.009 %-0.097 % and endotracheal intubation under general anesthesia being the most common cause.
View Article and Find Full Text PDFCureus
August 2024
Department of Anesthesiology, Saitama Medical University International Medical Center, Saitama, JPN.
Background: Second-generation supraglottic airway devices (SGAs) are pivotal in airway management, with the ability to accommodate gastric tube (GT) insertion. However, research on GT insertion with SGAs under controlled conditions is limited. This study aimed to evaluate the GT insertion performance of SGAs using a manikin.
View Article and Find Full Text PDFIndian J Anaesth
July 2024
Department of Anaesthesiology and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Background And Aims: Postoperative sore throat (POST) can be as high as 42% in supraglottic devices. LMA® Protector™ is a novel second-generation laryngeal mask airway (LMA) with Cuff Pilot™ technology that allows continuous cuff pressure monitoring. Elevated cuff pressure is a risk factor for POST in supraglottic devices, so we conducted this study to determine whether continuous cuff pressure monitoring can alleviate POST.
View Article and Find Full Text PDFAnn Card Anaesth
July 2024
Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
J Anaesthesiol Clin Pharmacol
April 2024
Department of Anaesthesia and Intensive Care, Government Medical College and Hospital, Chandigarh, India.
Background And Aims: Intra-cuff pressure of Air-Q self-pressurized laryngeal airways (Air-Q SP) balances airway pressure and adapts to patient's pharyngeal and periglottic structures, thus improves oropharyngeal leak pressure (OLP).This study was performed to compare efficacy of Air-Q SP with Proseal laryngeal mask airway (PLMA) in patients undergoing elective surgery.
Material And Methods: The study design was prospective, randomized and controlled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!