A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrodeposition of gold nanoparticles on indium/tin oxide electrode for fabrication of a disposable hydrogen peroxide biosensor. | LitMetric

A novel disposable third-generation hydrogen peroxide (H(2)O(2)) biosensor based on horseradish peroxidase (HRP) immobilized on the gold nanoparticles (AuNPs) electrodeposited indium tin oxide (ITO) electrode is investigated. The AuNPs deposited on ITO electrode were characterized by UV-vis, SEM, and electrochemical methods. The AuNPs attached on the ITO electrode surface with quasi-spherical shape and the average size of diameters was about 25 nm with a quite symmetric distribution. The direct electron chemistry of HRP was realized, and the biosensor exhibited excellent performances for the reduction of H(2)O(2). The amperometric response to H(2)O(2) shows a linear relation in the range from 8.0 micromol L(-1) to 3.0 mmol L(-1) and a detection limit of 2 micromol L(-1) (S/N=3). The K(M)(app) value of HRP immobilized on the electrode surface was found to be 0.4 mmol L(-1). The biosensor indicates excellent reproducibility, high selectivity and long-term stability.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2008.09.034DOI Listing

Publication Analysis

Top Keywords

ito electrode
12
gold nanoparticles
8
hydrogen peroxide
8
hrp immobilized
8
electrode surface
8
micromol l-1
8
mmol l-1
8
electrode
5
electrodeposition gold
4
nanoparticles indium/tin
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!