Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This work described methodology of Sn, Pb, Cd and Zn impurities determination in high-purity graphite at direct atomic absorption spectrometry (AAS) with flame furnace (FF) atomizer. It was evidence that quality of AAS measurements are depended from sample amount, its homogeneity, particle size, as well as calibration procedure and operation parameters of FF atomizer. Prior to analysis the method has been developed and optimized with respect to the furnace heating temperature and flame composition of FF atomizer. Conditions of absorption peak areas (Q(A)) formation to each element were studied on the basis of contribution into its value some of individual parameters of analytes, including mass-transporting process from increasing mass of graphite samples into gas phase. Because particle size and homogeneous distribution of analyte in powdered materials has an enormous influence on accuracy and precision of measurement results, graphite as well as appropriate series of powdered reference standards was previously ground and investigated. Graphite samples to be analyzed and standard reference materials with mass from 0.025 to 0.200g was previously briquetted as pellet and insert on corresponding hole in furnace. The characteristic mass (g(0)) of Sn, Pb, Cd and Zn were 0.35, 0.1, 0.008 and 0.025ng, respectively, and relative standard deviation (S(r)) not more than 20%.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2006.10.040 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!