A 46-year-old woman was admitted to our hospital because of bloody and chest pain. Chest X-ray and CT scan revealed a 17-mm nodule in the left upper lobe, consolidations in both lower lobes, and mediastinal and hilar lymphadenopathy. CT-guided lung biopsy from the right lower lobe revealed tumor cell embolism, intimal fibrocellular proliferation of small arteries, fibrin thrombi and recanalization. Embolic tumor cells were adenocarcinoma and immunohistologial staining for TTF-1 was positive. The patient was diagnosed as having pulmonary tumor thrombotic microangiopathy (PTTM) associated with clinical stage IV primary lung adenocarcinoma. Although chemotherapy with carboplatin and paclitaxel resulted in improvement of pulmonary consolidations, multiple bone metastatic lesions appeared. The patient was subsequently treated with docetaxel, and gemcitabine thereafter. This was the first reported case of PTTM associated with lung cancer and diagnosed antemortem by CT-guided biopsy. This suggests that CT-guided lung biopsy may be useful for diagnosis of PTTM, and enable establishment of appropriate cancer chemotherapy.
Download full-text PDF |
Source |
---|
Int J Surg
January 2025
Department of Thoracic Surgery, Shanghai General Hospital Shanghai Jiao Tong University School of Medicine, Shanghai, PRC.
Background: The localization of pulmonary nodules is crucial for surgical intervention. However, a safe, simple, and efficient method remains elusive. This study aims to evaluate the safety and feasibility of a newly developed preoperative localization method for pulmonary nodules called Rapid Localization of Pulmonary Nodules On-Site (RLPN-OS).
View Article and Find Full Text PDFJ Comput Assist Tomogr
January 2025
Interventional Treatment, First Hospital of Qinhuangdao.
Objective: To confirm that saline sealing of the needle trace after computed tomography (CT)-guided lung biopsy reduces the incidence of pneumothorax and chest tube insertion, and to observe its effects on pulmonary hemorrhage and hemoptysis.
Materials And Methods: Patients who underwent CT-guided lung biopsy at our hospital between January 2018 and January 2024 were included in the study. Patients were divided into 2 groups according to whether the needle trace was sealed with saline after tissue sampling.
Int J Surg
January 2025
Carcinoma Department of Traditional Chinese Medicine, Dianjiang People's Hospital of Chongqing, Chongqing, PR China.
The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.
View Article and Find Full Text PDFQuant Imaging Med Surg
January 2025
Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background: Accurate localization of small pulmonary nodules (SPNs) during video-assisted thoracoscopic surgery (VATS) is challenging due to the small size and deep location. Both the 4-hook wire technique and methylene blue are significant methods for preoperative localization of SPNs. This study aimed to compare the safety of both methods by monitoring and recording any surgery-related complications.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Thoracic Surgery, The Second Xiangya Hospital of Central South University, 139 Renmin Road, Changsha, 410011, Hunan, China.
Percutaneous transthoracic puncture of small pulmonary nodules is technically challenging. We developed a novel electromagnetic navigation puncture system for the puncture of sub-centimeter lung nodules by combining multiple deep learning models with electromagnetic and spatial localization technologies. We compared the performance of DL-EMNS and conventional CT-guided methods in percutaneous lung punctures using phantom and animal models.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!