Background: Primary laparoscopic hiatal hernia repair is associated with up to a 42% recurrence rate. This has lead to the use of mesh for crural repair, which has resulted in an improved recurrence rate (0-24%). However, mesh complications have been observed.
Methods: We compiled two cases, and our senior author contacted other experienced esophageal surgeons who provided 26 additional cases with mesh-related complications. Care was taken to retrieve technical operative details concerning mesh size and shape and implantation technique used.
Results: Twenty-six patients underwent laparoscopic and two patients open surgery for large hiatal hernia (n = 28). Twenty-five patients had a concomitant Nissen fundoplication, two a Toupet fundoplication, and one a Watson fundoplication. Mesh types placed were polypropylene (n = 8), polytetrafluoroethylene (PTFE) (n = 12), biological mesh (n = 7), and dual mesh (n = 1). Presenting symptoms associated with mesh complications were dysphagia (n = 22), heartburn (n = 10), chest pain (n = 14), fever (n = 1), epigastric pain (n = 2), and weight loss (n = 4). Main reoperative findings were intraluminal mesh erosion (n = 17), esophageal stenosis (n = 6), and dense fibrosis (n = 5). Six patients required esophagectomy, two patients had partial gastrectomy, and 1 patient had total gastrectomy. Five patients did not require surgery. In this group one patient had mesh removal by endoscopy. There was no immediate postoperative mortality, however one patient has severe gastroparesis and five patients are dependent on tube feeding. Two patients died 3 months postoperatively of unknown cause. There is no apparent relationship between mesh type and configuration with the complications encountered.
Conclusion: Complications related to synthetic mesh placement at the esophageal hiatus are more common than previously reported. Multicenter prospective studies are needed to determine the best method and type of mesh for implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-008-0205-5 | DOI Listing |
J Clin Med
January 2025
Academic Department of Trauma & Orthopaedics, School of Medicine, University of Leeds, Leeds LS2 9LU, UK.
Acetabular fractures are rare fractures of the pelvis which usually result from trauma. Whilst data are reported on sexual and genitourinary function in those with pelvic fractures, less is known about those with isolated acetabulum fractures. This systematic review aimed to determine, first, the frequency of sexual and genitourinary dysfunction following isolated acetabulum fractures and, second, the nature of these complications.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Obstetrics and Gynecology, University Hospital RWTH Aachen, 52074 Aachen, Germany.
: Transobturator tape (TOT) procedures are a widely used and effective treatment for stress urinary incontinence (SUI), but there is limited research on mesh-related complications and revision surgeries. This study aimed to evaluate the incidence of revision surgeries and mesh-related complications following TOT procedures and identify potential risk factors influencing these outcomes. : This retrospective study analyzed data from patients who underwent TOT procedures at the specialized incontinence center of University Hospital Aachen (UHA), Germany, between January 2010 and May 2023.
View Article and Find Full Text PDFJ Clin Med
December 2024
Oxford University Hospitals, NHS Foundation Trust, Oxford OX3 9DU, UK.
: Cervical mesonephric adenocarcinomas (MNACs) are among the rarest neoplasms of the female genital tract. Unlike the majority of cervical cancers, which are predominantly squamous in origin and strongly associated with HPV seropositivity, MNACs are distinct in both histology and pathophysiology. Despite their unique characteristics, MNACs have historically been managed in parallel with squamous cell carcinomas, resulting in a lack of optimised, evidence-based treatment protocols.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Management, Lublin University of Technology, 20-618 Lublin, Poland.
This article presents the results of experimental studies on the influence of the geometry of high-voltage plasma actuator electrodes on the change in flow in the boundary layer and their influence on the change in the lift coefficient. The plasma actuator used in the described experimental studies has a completely different structure. The experimental model of the plasma actuator uses a large mesh ground electrode and different geometries of the high-voltage electrodes, namely copper solid electrodes and mesh electrodes (the use of mesh electrodes, large GND and HV is a new solution).
View Article and Find Full Text PDFNutrients
December 2024
Centre for Diabetes, Obesity and Endocrinology Research (CDOER), Westmead Institute for Medical Research, Westmead, Sydney, NSW 2145, Australia.
Background: Recent findings have highlighted that abnormal energy metabolism is a key feature of autosomal-dominant polycystic kidney disease (ADPKD). Emerging evidence suggests that nutritional ketosis could offer therapeutic benefits, including potentially slowing or even reversing disease progression. This systematic review aims to synthesise the literature on ketogenic interventions to evaluate the impact in ADPKD.